Portable design with uncompromised performance
Depend on Thermo Scientific Orion AQUAfast colorimeters for simple, accurate, and portable instruments for your water analysis. Offering a wide range of methods, optimum wavelengths, user-friendly displays, and easy calibration, AQUAfast colorimetry meters are fieldwork essentials.
Speak to specialist
Colorimetry instruments
Go where you need to go for your water analysis needs with any AQUAfast Portable Colorimeter. Choose between four models and 134 preprogrammed methods to measure the concentrations of sample components.
Advanced reliability when you need it most
| |
Sophisticated capability, basic affordability
| |
Free and total chlorine detection made easy
| |
Exclusive focus on chemical oxygen demand detection
|
Browse all reagents and accessories available for your colorimeter
Chemical species | Method Description | Method | Form Factor | Range | Shop |
Alkalinity | -M, Acid/Indicator Method, 100 tests | AC2002 | Tablet | 5 – 200 mg/L | |
-P, Acid/Indicator Method, 100 tests | AC3002P | Tablet | 5 – 300 mg/L | ||
Aluminum | Eriochrome Cyanine R Method, 50 tests | AC2027 | Tablet | 0.01 – 0.3 mg/L | |
Eriochrome Cyanine R Method, 100 tests | AC4P27 | Powder | 0.01 – 0.25 mg/L | ||
Ammonia as Nitrogen | High Range, Salicylate Method, 50 tubes | ACR011 | Reaction Tube | 1 – 50 mg/L | |
Indophenol Phenate Method, 50 tests | AC2012 | Tablet | 0.02 – 1 mg/L | ||
Low Range, Salicylate Method, 50 tubes | ACR012 | Reaction Tube | 0.02 – 2.5 mg/L | ||
Salicylate Method, 100 tests | AC4P12 | Powder | 0.01 – 0.8 mg/L | ||
Bromine | DPD Method, 100 tests | AC2035 | Tablet | 0.05 – 13 mg/L | |
Chloride | Silver Nitrate/Turbidity Method, 50 tests | AC2017 | Tablet | 0.5 – 25 mg/L | |
Chlorine Dioxide | DPD Method, 100 tests | AC2099 | Tablet | 0.02 – 11 mg/L | |
Chlorine | Free & Total, DPD Method, 100 tests | AC2070 | Tablet | 0.01 – 6 mg/L | |
Free, DPD bulk powder dispenser with one vial x 250 tests | AQ250F | Powder | 0.02 – 2 mg/L Cl2 | ||
Free, DPD Method, 100 tests | AC2071 | Tablet | 0.01 – 6 mg/L | ||
Free, DPD Method, 100 tests | AC4P71 | Powder | 0.02 – 2 mg/L | ||
Free, DPD powder refill for AQ250F dispenser, 1 vial x 250 tests | AC71P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Free, DPD powder refill for AQ250F dispenser, 2 vials x 250 tests each | AC71P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Total, DPD Method, 100 tests | AC2072 | Tablet | 0.01 – 6mg /L | ||
Total, DPD Method, 100 tests | AC4P72 | Powder | 0.02 – 2 mg/L | ||
Total, DPD powder dispenser with one vial x 250 tests | AQ250T | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder dispenser with one vial x 250 count* | |
Total, DPD powder refill for AQ250T dispenser, 1 vial x 250 tests | AC72P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder refill for AQ250T dispenser* | |
Total, DPD powder refill for AQ250T dispenser, 2 vials x 250 tests each | AC72P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Total, High Range, KI/Acid Method, 100 tests | AC3072 | Tablet | 5 – 200 mg/L | AQUAfast chlorine (total) HR & sodium chlorate reagent tablets | |
COD | Low Range, Dichromate Closed Reflux Method, 25 Tests | CODL00 | Digestion Tube | 0 - 150mg/L | |
Low Range, Dichromate Closed Reflux Method, 150 Tests | CODL150 | Digestion Tube | 0 to 150mg/L O2 | ||
Mid Range, Dichromate Closed Reflux Method, 25 Tests | CODH00 | Digestion Tube | 0 - 1,500mg/L | ||
Mid Range,Dichromate Closed Reflux Method, 150 Tests | CODM150 | Digestion Tube | 0 to 1,500mg/L O2 | ||
High Range, Dichromate Closed Reflux Method, 25 Tests | CODHP0 | Digestion Tube | 0 - 15,000mg/L | ||
High Range, Dichromate Closed Reflux Method, 150 Tests | CODH150 | Digestion Tube | 0 to 15,000mg/L O2 | AQUAfast Digestion Tubes, Range: 0 to 15000 mg/L O2, COD High Range* | |
Copper | Free & Total, Biquinoline, 50 tests | AC2029 | Method Tablet L | 0.05 - 5mg/ | |
Free, Bicinchoninate, 100 tests | AC4P29 | Method Powder | 0.05 - 5mg/L | ||
Cyanuric Acid | Melamine Method, 100 tests | AC2098 | Tablet | 0 – 160 mg/L | |
DEHA | PPST Method, 100 tests | AC4P88 | Digestion Tubes and Liquid | 0.02 – 0.5 mg/L | |
Fluoride | SPADNS Kit Method, 50 tests | AC2009 | Liquid | 0.05 – 2 mg/L | |
Hardness | Calcium, Low Range, Murexide Method, 100 tests | AC3032C2 | Tablet | 0 – 500 mg/L | AQUAfast hardness (calcium) LR reagent tablets, Murexide Method |
Calcium, High Range, Murexide Method, 100 tests | AC3032C | Tablet | 50 – 900 mg/L | AQUAfast hardness (calcium) HR reagent tablets, Murexide Method | |
Total, Metallphthlein Method, 100 tests | AC3032T | Tablet | 2 – 50 mg/L | AQUAfast hardness (total) reagent tablets, Metallphthalein Method | |
Hydrazine | 4-(Dimethyl-amino)-Benzaldehyde Method, 30 tests | AC2030 | Powder | 0.05 - 0.5 mg/L | |
Hydrogen Peroxide | DPD/Catalyst Method, 100 tests | AC3069 | Tablet | 0.03 – 3 mg/L | |
Iron | (II & III), PPST Method, 100 tests | AC2078 | Tablet | 0.02 – 1 mg/L | |
Ferro, 1,10-Phenanthroline Method, 100 packs | AC4P78 | Powder | 0.02 – 3 mg/L | ||
Total, TPTZ Method, 100 tests | AC4P79 | Powder | 0.02 - 1.8 mg/L | ||
Manganese | Formaldoxime Method, 50 tests | AC2055 | Tablet | 0.2 – 4 mg/L | |
High Range, Periodate Oxidation Method, 100 tests | AC4P55 | Powder | 0.1 – 18 mg/L | ||
Low Range, PAN Method, 100 tests | AC4P54 | Digestion Tubes and Liquid | 0.01 – 0.7mg/L | ||
Molybdate / Molybdenum | Mercaptoacetic Acid Method, 100 tests | AC4P42 | Powder | 0.5 – 66 mg/L | |
Nitrate as Nitrogen (N) | Chromotropic Acid Method, 50 tests | ACR007 | Reaction Tube | 1 – 30 mg/L | |
Zinc Reduction Method, 50 tests | AC2007 | Tablet | 0.08 – 1 mg/L | ||
Diazotization (Azo) Method, 100 tests | AC4P46 | Powder | 0.01 – 0.3 mg/L | ||
N-(1-Naphthyl)-Ethylenediamine Method, 100 tests, 50 tests | AC2046 | Tablet | 0.01 – 0.5 mg/L | ||
Nitrogen | Total, High Range, Persulfate Digestion Method, 50 tests | ACD007 | Digestion Tube | 5 – 150 mg/L | |
Total, Low Range, Persulfate Digestion Method, 50 pack | ACD004 | Digestion Tube | 0.5 – 25 mg/L | ||
pH | pH, Bromocresol Purple Method, 100 tests | AC3001BP | Tablet | 5.2 – 6.8 pH | |
pH, Phenol Red Method, 100 tests | AC2001 | Tablet | 6.5 – 8.4 pH | ||
pH, Phenol Red Method, 30 tests | AC3001 | Liquid | 6.5 – 8.4 pH | ||
pH, Thymol Blue Method, 100 tests | AC3001TB | Tablet | 8.0 – 9.6 pH | ||
Phosphorous as P | Acid Hydrolyzable, Acid Digestion/Ascorbic Acid Method, 50 tests | ACD095AH | Digestion Tube | 0.02 – 1.6 mg/L | |
Total, Persulfate Digestion/Ascorbic Acid Method, 50 tests | ACD095 | Digestion Tube | 0.02 – 1 mg/L | ||
Phosphate | Ortho,Phosphomolybdenum/Ascorbic Acid Method, 100 tests | AC4P95 | Powder | 0.06 – 2.5 mg/L | |
Ortho, Phosphomolybdenum/ Ascorbic Acid Method, 50 tubes | ACR095 | Reaction Tube | 0.06 – 5mg/L | ||
Ortho, Phosphomolybdic Acid/ Ascorbic Acid Method, 50 tests | AC2095-WA | Tablet | 0.05 – 4 mg/L | ||
Ortho, Ascorbic Acid/Vanadomolybdate Method, 50 tests | AC2096 | Tablet | 1 – 80 mg/L | ||
Potassium | Tetraphenylborate-Turbidity Method, 100 tests | AC3019 | Tablet | 0.7 – 12 mg/L | |
Silica | High Range, Silicomolybdate Method, 100 tests | AC4P60 | Powder | 1 – 90 mg/L | |
Silicomolybdate, Heteropoly Blue Method, 50 tests | AC2060 | Tablet | 0.05 – 4 mg/L | ||
Phosphate Removal for AC2060 Method, 100 tablets | AC2061 | Tablet | --- | ||
Sodium | Hypochlorite, Potassium Iodide Method, 100 tests | AC3072 | Tablet | 0.2 – 16% NaOCl | AQUAfast chlorine (total) HR & sodium chlorate reagent tablets |
Sulfate | Barium Sulfate/Turbidity Method, 100 tests | AC2082 | Tablet | 5 – 100 mg/L | |
Barium Sulfate/Turbidity Method, 100 tests | AC4P82 | Powder | 5 – 100 mg/L | ||
Sulfide | DPD/Catalyst Method, 50 tests | AC2016 | Tablet | 0.04 – 0.5 mg/L | |
Zinc | Zincon Method, 50 tests | AC2065 | Tablet | 0.02 – 1 mg/L |
*Compliant with US EPA and other global testing methods for COD in wastewater
Accessories for use with the AQUAfast AQ3700 Colorimeter
Cat. No. | Description | |
AC2V16 | Replacement 16mm vials, 10/pack | Shop |
AC2V24 | Replacement 24mm vials, 12/pack | Shop |
AC3VSK | Verification standard kit, set of 6 | Shop |
AC3CBR | Vial cleaning brush, 5/pack | |
COD165 | Digestion methods thermoreactor, pre-set for 100°, 120°, 150°, 160°, and 165°C | Shop |
CODS01 | COD standard, 1,000ppm, 475mL | Shop |
CODS01 | COD standard, 1,000ppm, 475mL | Shop |
Chemical species | Method Description | Method | Form Factor | Range | Shop |
Alkalinity | -M, Acid/Indicator Method, 100 tests | AC2002 | Tablet | 5 – 200 mg/L | |
Aluminum | Eriochrome Cyanine R Method, 50 tests | AC2027 | Tablet | 0.01 – 0.3 mg/ | |
Ammonia as Nitrogen | High Range, Nesslerization Method, 30 pack | AC4011 | Reaction Tube | 1 – 14 mg/L | |
Indophenol Phenate Method, 50 tests | AC2012 | Tablet | 0.02 – 1 mg/L | ||
Low Range, Nessler Method, 30 pack | AC4012 | Reaction Tube | 0.5 – 7 mg/L | ||
Salicylate Method, 100 tests | AC4P12 | Powder | 0.01 – 0.8 mg/L | ||
Salicylate Method, 30 pack | AC4010 | Ampoule | 0.2 – 3 mg/L; 2 – 30 mg/L | ||
Chloride | Ferricyanide (Ferric Thiocyanate) Method, 30 tests | AC4017 | Ampoule | 2.5 – 40 mg/L | |
Silver Nitrate/Turbidity Method, 50 tests | AC2017 | Tablet | 0.5 – 25 mg/L | ||
Chlorine Dioxide | DPD Method, 30 tests | AC4099 | Ampoule | 0.8 – 11 mg/L | |
Chlorine | Free & Total, DPD Method, 100 tests | AC2070 | Tablet | 0.01 – 6 mg/L Cl2 | |
Free & Total, DPD Method, 30 tests | AC4070 | Ampoule | 0.4 – 5 mg/L Cl2 | ||
Free, DPD bulk powder dispenser with one vial x 250 tests | AQ250F | Powder | 0.02 – 2 mg/L Cl2 | ||
Free, DPD Method | AC2071 | Tablet | 0.01 – 6 mg/L Cl2 | ||
Free, DPD Method | AC4P71 | Powder | 0.02 – 2 mg/L Cl2 | ||
Free, DPD powder refill for AQ250F dispenser, 1 vial x 250 tests | AC71P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Free, DPD powder refill for AQ250F dispenser, 2 vials x 250 tests each | AC71P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Total, DPD Method, 100 tests | AC2072 | Tablet | 0.01 – 6mg /L Cl2 | ||
Total, DPD Method, 100 tests | AC4P72 | Powder | 0.02 – 2 mg/L Cl2 | ||
Total, DPD powder dispenser with one vial x 250 tests | AQ250T | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder dispenser with one vial x 250 count* | |
Total, DPD powder refill for AQ250T dispenser, 1 vial x 250 tests | AC72P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder refill for AQ250T dispenser* | |
Total, DPD powder refill for AQ250T dispenser, 2 vials x 250 tests each | AC72P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
COD | Low Range, Dichromate closed reflux Method, 25 Tests | CODL00 | Digestion Tube | 0 – 150mg/L | |
Low Range, Dichromate closed reflux Method, 150 Tests | CODL150 | Digestion Tube | 0 – 150mg/L O2 | ||
Mid Range, Dichromate closed reflux Method, 25 Tests | CODH00 | Digestion Tube | 0 – 1,500mg/L | ||
Mid Range, Dichromate closed reflux Method, 150 Tests | CODM150 | Digestion Tube | 0 – 1,500mg/L O2 | ||
High Range, Dichromate closed reflux Method, 25 Tests | CODHPO | Digestion Tube | 0 – 15,000mg/L O2 | ||
High Range, Dichromate closed reflux Method, 150 Tests | CODH150 | Digestion Tube | 0 – 15,000mg/L O2 | AQUAfast Digestion Tubes, Range: 0 to 15000 mg/L O2, COD High Range* | |
Copper | Free & Total, Biquinoline, 50 tests | AC2029 | Tablet | 0.05 – 5mg/L | |
Free, Bicinchoninate, 100 tests | AC4P29 | Powder | 0.05 – 5mg/L | ||
Cyanide | Isonicotinic-Barbituric Acid Method, 30 tests | AC4006 | Ampoule | 0.04 – 0.4mg/L | |
Fluoride | SPADNS Kit Method, 50 tests | AC2009 | Liquid | 0.05 – 2 mg/L | |
Hydrazine | 4-(Dimethyl-amino)-Benzaldehyde Method, 30 tests | AC2030 | Powder | 0.05 – 0.5 mg/L | |
Iron | (II & III), PPST Method, 100 tests | AC2078 | Tablet | 0.02 – 1 mg/L | |
Ferro, 1,10-Phenanthroline Method, 100 tests | AC4P78 | Powder | 0.02 – 3 mg/L | ||
Total & Soluble, Phenanthroline Method, 30 tests | AC4078 | Ampoule | 0.2 – 6 mg/L | ||
Total, TPTZ Method, 100 tests | AC4P79 | Powder | 0.02 – 1.8 mg/L | ||
Manganese | Formaldoxime Method, 50 tests | AC2055 | Tablet | 0.2 – 4 mg/L | |
High Range, Periodate Oxidation Method, 100 tests | AC4P55 | Powder | 0.1 – 18 mg/L | ||
Periodate Method, 30 tests | AC4055 | Ampoule | 2 – 30 mg/L | ||
Molybdate / Molybdenum | Mercaptoacetic Acid Method, 100 tests | AC4P42 | Powder | 0.5 – 66 mg/L | |
Nitrate as Nitrogen (N) | Cadmium Reduction Method, 30 tests | AC4004 | Ampoule | 0.2 – 1.5 mg/L | |
Cadmium Reduction Method, 30 tests | AC4005 | Ampoule | 2.0 – 7.50 mg/L | ||
Zinc Reduction Method, 50 tests | AC2007 | Tablet | 0.08 – 1 mg/L | ||
Cadmium Reduction Method, 30 tests | AC4007 | Ampoule | 5 – 50 mg/L | ||
Diazotization (NED) Method | AC4P46 | Powder | 0.01 – 0.3 mg/L | ||
Diazotization (NED) Method | AC4046 | Tablet | 0.08 – 1 mg/L | ||
Diazotization (NED) Method | AC2046 | Tablet | 0.01 – 0.5 mg/L | ||
Ozone | DPD Method, 30 tests | AC4048 | Ampoule | 0.2 – 5 pH | |
pH | Phenol Red Method, 100 tests | AC2001 | Tablet | 6.5 – 8.4 pH | |
Phosphate | Phosphate, Ortho, Phosphomolybdenum/Ascorbic Acid Method, 100 tests | AC4P95 | Powder
| 0.06 – 2.5 mg/L | |
Phosphate, Ortho, Phosphomolybdic Acid/Ascorbic Acid Method, 50 tests | AC2095-WA | Tablet
| 0.05 – 4 mg/L | ||
Ortho, Stannous Chloride Method, 30 tests | g | Reaction Tube | 0.3 – 8 mg/L | ||
Phosphate, Ortho, Ascorbic Acid/Vanadomolybdate Method, 50 tests | AC2096 | Tablet | 1 – 80 mg/L | ||
Silica | Heteropoly Blue Method, 30 tests | AC4060 | Ampoule | 0.5 – 10 mg/L | |
Phosphate Removal for AC2060 Method, 100 tests | AC2061 | Tablet | ---- | ||
High Range, Silicomolybdate Method, 100 tests | AC4P60 | Powder | 1 – 90 mg/L | ||
Silicomolybdate, Heteropoly Blue Method, 50 tests | AC2060 | Tablet | 0.05 – 4 mg/L | ||
Sulfate | Barium Sulfate/Turbidity Method, 100 tests | AC2082 | Tablet | 5 – 100 mg/L | |
Barium Sulfate/Turbidity Method, 30 tests | AC4082 | Ampoule | 8 – 100 mg/L | ||
Barium Sulfate/Turbidity Method, 100 tests | AC4P82 | Powder | 5 – 100 mg/L | ||
Sulfide | Acid Soluble, Methylene Blue Method, 30 tests | AC4016 | Ampoule | 0.2 – 3 mg/L | |
DPD/Catalyst Method, 50 tests | AC2016 | Tablet | 0.04 – 0.5 mg/L | ||
Zinc
| Zinc, Zincon Method, 50 tests | AC2065 | Tablet | 0.02 – 1 mg/L | |
Zinc, Zincon Method, 30 pack | AC4065 | Auto-ID Ampoule | 0.3 – 3 mg/L |
*Compliant with US EPA and other global testing methods for COD in wastewater
Accessories for use with the AQUAfast AQ4000 Colorimeter
Cat. No. | Description |
|
AC2V16 | Replacement 16mm vials, 10/pack | |
AC2V24 | Replacement 24mm vials, 12/pack | |
AC3CBR | Vial cleaning brush, 5/pack | |
AQ4CBL | RS232 cable for data download and software update | |
AQ4ZER | AQUAfast Zero Kit | |
COD165 | Digestion methods thermoreactor, pre-set for 100°, 120°, 150°, 160°, and 165°C | |
CODS01 | COD standard, 1000ppm, 475mL | |
CODS10 | COD standard, 10000ppm, 475mL | |
CLSK100 | Chlorine primary standard, 1.5mg/L ampoule kit | |
AC3ROD | Crush and stir rod for tablets and AC2V24 vials |
Chemical species | Method Description | Method | Form Factor | Range | Shop |
Chlorine | |||||
Free, DPD Method, 100 tests | AC4P71 | Powder | 0.02 – 2 mg/L Cl2; 0.1 – 8 mg/L Cl2+ | ||
Free, DPD bulk powder dispenser with one vial x 250 tests | AQ250F | Powder | 0.02 – 2 mg/L Cl2 | ||
Free, DPD powder refill for AQ250F dispenser, 1 vial x 250 tests | AC71P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Free, DPD powder refill for AQ250F dispenser, 2 vials x 250 tests each | AC71P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Total, DPD Method, 100 tests | AC4P72 | Powder | 0.02 – 2 mg/L Cl2; 0.1 – 8 mg/L Cl2+ | ||
Total, Bluk DPD powder dispenser with one vial x 250 tests | AQ250T | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder dispenser with one vial x 250 count* | |
Total, DPD powder refill for AQ250T dispenser, 1 vial x 250 tests | AC72P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder refill for AQ250T dispenser* | |
Total, DPD powder refill for AQ250T dispenser, 2 vials x 250 tests each | AC72P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* |
† Use AC2V10 short path length plastic vials and two powder packs.
*Compliant with US EPA and other global testing methods for COD in wastewater
Accessories for use with the AQUAfast AQ3170 Colorimeter
Cat. No. | Description |
|
AC2V24 | Replacement 24mm vials, 12/pack | |
AC2V10 | AQUAfast 10mm short path length plastic vials for high-level chlorine, 12/pack | |
CLSK100 | Chlorine primary standard, 1.5mg/L ampoule kit | |
CLSK200 | Chlorine secondary standards (0.0, 0.2, and 1mg/L) | |
AC3CBR | Vial cleaning brush, 5/pack |
Chemical species | Method Description | Method | Form Factor | Range | Shop |
COD | Low Range, Dichromate Digestion Method, 25 Tests | CODL00 | Digestion Tube | 0 – 150mg/L | |
Low Range, Dichromate Digestion Method, 150 Tests | CODL150 | Digestion Tube | 0 – 150mg/L O2 | ||
Mid Range, Dichromate Digestion Method, 25 Tests | CODH00 | Digestion Tube | 0 – 1,500mg/L | ||
Mid Range,Dichromate Digestion Method, 150 Tests | CODM150 | Digestion Tube | 0 – 1,500mg/L O2 | ||
High Range, Dichromate Digestion Method, 25 Tests | CODHP0 | Digestion Tube | 0 – 15,000mg/L | AQUAfast Digestion Tubes, Range: 0-15000 mg/L O2 COD High Range* | |
High Range, Dichromate Digestion Method, 150 Tests | CODH150 | Digestion Tube | 0 – 15,000mg/L O2 | AQUAfast Digestion Tubes, Range: 0 to 15000 mg/L O2, COD High Range* |
*Compliant with US EPA and other global testing methods for COD in wastewater
Accessories for use with the AQUAfast AQ3140 COD Colorimeter
Chemical species | Method Description | Method | Form Factor | Range | Shop |
Alkalinity | -M, Acid/Indicator Method, 100 tests | AC2002 | Tablet | 5 – 200 mg/L | |
-P, Acid/Indicator Method, 100 tests | AC3002P | Tablet | 5 – 300 mg/L | ||
Aluminum | Eriochrome Cyanine R Method, 50 tests | AC2027 | Tablet | 0.01 – 0.3 mg/L | |
Eriochrome Cyanine R Method, 100 tests | AC4P27 | Powder | 0.01 – 0.25 mg/L | ||
Ammonia as Nitrogen | High Range, Salicylate Method, 50 tubes | ACR011 | Reaction Tube | 1 – 50 mg/L | |
Indophenol Phenate Method, 50 tests | AC2012 | Tablet | 0.02 – 1 mg/L | ||
Low Range, Salicylate Method, 50 tubes | ACR012 | Reaction Tube | 0.02 – 2.5 mg/L | ||
Salicylate Method, 100 tests | AC4P12 | Powder | 0.01 – 0.8 mg/L | ||
Bromine | DPD Method, 100 tests | AC2035 | Tablet | 0.05 – 13 mg/L | |
Chloride | Silver Nitrate/Turbidity Method, 50 tests | AC2017 | Tablet | 0.5 – 25 mg/L | |
Chlorine Dioxide | DPD Method, 100 tests | AC2099 | Tablet | 0.02 – 11 mg/L | |
Chlorine | Free & Total, DPD Method, 100 tests | AC2070 | Tablet | 0.01 – 6 mg/L | |
Free, DPD bulk powder dispenser with one vial x 250 tests | AQ250F | Powder | 0.02 – 2 mg/L Cl2 | ||
Free, DPD Method, 100 tests | AC2071 | Tablet | 0.01 – 6 mg/L | ||
Free, DPD Method, 100 tests | AC4P71 | Powder | 0.02 – 2 mg/L | ||
Free, DPD powder refill for AQ250F dispenser, 1 vial x 250 tests | AC71P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Free, DPD powder refill for AQ250F dispenser, 2 vials x 250 tests each | AC71P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Total, DPD Method, 100 tests | AC2072 | Tablet | 0.01 – 6mg /L | ||
Total, DPD Method, 100 tests | AC4P72 | Powder | 0.02 – 2 mg/L | ||
Total, DPD powder dispenser with one vial x 250 tests | AQ250T | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder dispenser with one vial x 250 count* | |
Total, DPD powder refill for AQ250T dispenser, 1 vial x 250 tests | AC72P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder refill for AQ250T dispenser* | |
Total, DPD powder refill for AQ250T dispenser, 2 vials x 250 tests each | AC72P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Total, High Range, KI/Acid Method, 100 tests | AC3072 | Tablet | 5 – 200 mg/L | AQUAfast chlorine (total) HR & sodium chlorate reagent tablets | |
COD | Low Range, Dichromate Closed Reflux Method, 25 Tests | CODL00 | Digestion Tube | 0 - 150mg/L | |
Low Range, Dichromate Closed Reflux Method, 150 Tests | CODL150 | Digestion Tube | 0 to 150mg/L O2 | ||
Mid Range, Dichromate Closed Reflux Method, 25 Tests | CODH00 | Digestion Tube | 0 - 1,500mg/L | ||
Mid Range,Dichromate Closed Reflux Method, 150 Tests | CODM150 | Digestion Tube | 0 to 1,500mg/L O2 | ||
High Range, Dichromate Closed Reflux Method, 25 Tests | CODHP0 | Digestion Tube | 0 - 15,000mg/L | ||
High Range, Dichromate Closed Reflux Method, 150 Tests | CODH150 | Digestion Tube | 0 to 15,000mg/L O2 | AQUAfast Digestion Tubes, Range: 0 to 15000 mg/L O2, COD High Range* | |
Copper | Free & Total, Biquinoline, 50 tests | AC2029 | Method Tablet L | 0.05 - 5mg/ | |
Free, Bicinchoninate, 100 tests | AC4P29 | Method Powder | 0.05 - 5mg/L | ||
Cyanuric Acid | Melamine Method, 100 tests | AC2098 | Tablet | 0 – 160 mg/L | |
DEHA | PPST Method, 100 tests | AC4P88 | Digestion Tubes and Liquid | 0.02 – 0.5 mg/L | |
Fluoride | SPADNS Kit Method, 50 tests | AC2009 | Liquid | 0.05 – 2 mg/L | |
Hardness | Calcium, Low Range, Murexide Method, 100 tests | AC3032C2 | Tablet | 0 – 500 mg/L | AQUAfast hardness (calcium) LR reagent tablets, Murexide Method |
Calcium, High Range, Murexide Method, 100 tests | AC3032C | Tablet | 50 – 900 mg/L | AQUAfast hardness (calcium) HR reagent tablets, Murexide Method | |
Total, Metallphthlein Method, 100 tests | AC3032T | Tablet | 2 – 50 mg/L | AQUAfast hardness (total) reagent tablets, Metallphthalein Method | |
Hydrazine | 4-(Dimethyl-amino)-Benzaldehyde Method, 30 tests | AC2030 | Powder | 0.05 - 0.5 mg/L | |
Hydrogen Peroxide | DPD/Catalyst Method, 100 tests | AC3069 | Tablet | 0.03 – 3 mg/L | |
Iron | (II & III), PPST Method, 100 tests | AC2078 | Tablet | 0.02 – 1 mg/L | |
Ferro, 1,10-Phenanthroline Method, 100 packs | AC4P78 | Powder | 0.02 – 3 mg/L | ||
Total, TPTZ Method, 100 tests | AC4P79 | Powder | 0.02 - 1.8 mg/L | ||
Manganese | Formaldoxime Method, 50 tests | AC2055 | Tablet | 0.2 – 4 mg/L | |
High Range, Periodate Oxidation Method, 100 tests | AC4P55 | Powder | 0.1 – 18 mg/L | ||
Low Range, PAN Method, 100 tests | AC4P54 | Digestion Tubes and Liquid | 0.01 – 0.7mg/L | ||
Molybdate / Molybdenum | Mercaptoacetic Acid Method, 100 tests | AC4P42 | Powder | 0.5 – 66 mg/L | |
Nitrate as Nitrogen (N) | Chromotropic Acid Method, 50 tests | ACR007 | Reaction Tube | 1 – 30 mg/L | |
Zinc Reduction Method, 50 tests | AC2007 | Tablet | 0.08 – 1 mg/L | ||
Diazotization (Azo) Method, 100 tests | AC4P46 | Powder | 0.01 – 0.3 mg/L | ||
N-(1-Naphthyl)-Ethylenediamine Method, 100 tests, 50 tests | AC2046 | Tablet | 0.01 – 0.5 mg/L | ||
Nitrogen | Total, High Range, Persulfate Digestion Method, 50 tests | ACD007 | Digestion Tube | 5 – 150 mg/L | |
Total, Low Range, Persulfate Digestion Method, 50 pack | ACD004 | Digestion Tube | 0.5 – 25 mg/L | ||
pH | pH, Bromocresol Purple Method, 100 tests | AC3001BP | Tablet | 5.2 – 6.8 pH | |
pH, Phenol Red Method, 100 tests | AC2001 | Tablet | 6.5 – 8.4 pH | ||
pH, Phenol Red Method, 30 tests | AC3001 | Liquid | 6.5 – 8.4 pH | ||
pH, Thymol Blue Method, 100 tests | AC3001TB | Tablet | 8.0 – 9.6 pH | ||
Phosphorous as P | Acid Hydrolyzable, Acid Digestion/Ascorbic Acid Method, 50 tests | ACD095AH | Digestion Tube | 0.02 – 1.6 mg/L | |
Total, Persulfate Digestion/Ascorbic Acid Method, 50 tests | ACD095 | Digestion Tube | 0.02 – 1 mg/L | ||
Phosphate | Ortho,Phosphomolybdenum/Ascorbic Acid Method, 100 tests | AC4P95 | Powder | 0.06 – 2.5 mg/L | |
Ortho, Phosphomolybdenum/ Ascorbic Acid Method, 50 tubes | ACR095 | Reaction Tube | 0.06 – 5mg/L | ||
Ortho, Phosphomolybdic Acid/ Ascorbic Acid Method, 50 tests | AC2095-WA | Tablet | 0.05 – 4 mg/L | ||
Ortho, Ascorbic Acid/Vanadomolybdate Method, 50 tests | AC2096 | Tablet | 1 – 80 mg/L | ||
Potassium | Tetraphenylborate-Turbidity Method, 100 tests | AC3019 | Tablet | 0.7 – 12 mg/L | |
Silica | High Range, Silicomolybdate Method, 100 tests | AC4P60 | Powder | 1 – 90 mg/L | |
Silicomolybdate, Heteropoly Blue Method, 50 tests | AC2060 | Tablet | 0.05 – 4 mg/L | ||
Phosphate Removal for AC2060 Method, 100 tablets | AC2061 | Tablet | --- | ||
Sodium | Hypochlorite, Potassium Iodide Method, 100 tests | AC3072 | Tablet | 0.2 – 16% NaOCl | AQUAfast chlorine (total) HR & sodium chlorate reagent tablets |
Sulfate | Barium Sulfate/Turbidity Method, 100 tests | AC2082 | Tablet | 5 – 100 mg/L | |
Barium Sulfate/Turbidity Method, 100 tests | AC4P82 | Powder | 5 – 100 mg/L | ||
Sulfide | DPD/Catalyst Method, 50 tests | AC2016 | Tablet | 0.04 – 0.5 mg/L | |
Zinc | Zincon Method, 50 tests | AC2065 | Tablet | 0.02 – 1 mg/L |
*Compliant with US EPA and other global testing methods for COD in wastewater
Accessories for use with the AQUAfast AQ3700 Colorimeter
Cat. No. | Description | |
AC2V16 | Replacement 16mm vials, 10/pack | Shop |
AC2V24 | Replacement 24mm vials, 12/pack | Shop |
AC3VSK | Verification standard kit, set of 6 | Shop |
AC3CBR | Vial cleaning brush, 5/pack | |
COD165 | Digestion methods thermoreactor, pre-set for 100°, 120°, 150°, 160°, and 165°C | Shop |
CODS01 | COD standard, 1,000ppm, 475mL | Shop |
CODS01 | COD standard, 1,000ppm, 475mL | Shop |
Chemical species | Method Description | Method | Form Factor | Range | Shop |
Alkalinity | -M, Acid/Indicator Method, 100 tests | AC2002 | Tablet | 5 – 200 mg/L | |
Aluminum | Eriochrome Cyanine R Method, 50 tests | AC2027 | Tablet | 0.01 – 0.3 mg/ | |
Ammonia as Nitrogen | High Range, Nesslerization Method, 30 pack | AC4011 | Reaction Tube | 1 – 14 mg/L | |
Indophenol Phenate Method, 50 tests | AC2012 | Tablet | 0.02 – 1 mg/L | ||
Low Range, Nessler Method, 30 pack | AC4012 | Reaction Tube | 0.5 – 7 mg/L | ||
Salicylate Method, 100 tests | AC4P12 | Powder | 0.01 – 0.8 mg/L | ||
Salicylate Method, 30 pack | AC4010 | Ampoule | 0.2 – 3 mg/L; 2 – 30 mg/L | ||
Chloride | Ferricyanide (Ferric Thiocyanate) Method, 30 tests | AC4017 | Ampoule | 2.5 – 40 mg/L | |
Silver Nitrate/Turbidity Method, 50 tests | AC2017 | Tablet | 0.5 – 25 mg/L | ||
Chlorine Dioxide | DPD Method, 30 tests | AC4099 | Ampoule | 0.8 – 11 mg/L | |
Chlorine | Free & Total, DPD Method, 100 tests | AC2070 | Tablet | 0.01 – 6 mg/L Cl2 | |
Free & Total, DPD Method, 30 tests | AC4070 | Ampoule | 0.4 – 5 mg/L Cl2 | ||
Free, DPD bulk powder dispenser with one vial x 250 tests | AQ250F | Powder | 0.02 – 2 mg/L Cl2 | ||
Free, DPD Method | AC2071 | Tablet | 0.01 – 6 mg/L Cl2 | ||
Free, DPD Method | AC4P71 | Powder | 0.02 – 2 mg/L Cl2 | ||
Free, DPD powder refill for AQ250F dispenser, 1 vial x 250 tests | AC71P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Free, DPD powder refill for AQ250F dispenser, 2 vials x 250 tests each | AC71P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Total, DPD Method, 100 tests | AC2072 | Tablet | 0.01 – 6mg /L Cl2 | ||
Total, DPD Method, 100 tests | AC4P72 | Powder | 0.02 – 2 mg/L Cl2 | ||
Total, DPD powder dispenser with one vial x 250 tests | AQ250T | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder dispenser with one vial x 250 count* | |
Total, DPD powder refill for AQ250T dispenser, 1 vial x 250 tests | AC72P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder refill for AQ250T dispenser* | |
Total, DPD powder refill for AQ250T dispenser, 2 vials x 250 tests each | AC72P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
COD | Low Range, Dichromate closed reflux Method, 25 Tests | CODL00 | Digestion Tube | 0 – 150mg/L | |
Low Range, Dichromate closed reflux Method, 150 Tests | CODL150 | Digestion Tube | 0 – 150mg/L O2 | ||
Mid Range, Dichromate closed reflux Method, 25 Tests | CODH00 | Digestion Tube | 0 – 1,500mg/L | ||
Mid Range, Dichromate closed reflux Method, 150 Tests | CODM150 | Digestion Tube | 0 – 1,500mg/L O2 | ||
High Range, Dichromate closed reflux Method, 25 Tests | CODHPO | Digestion Tube | 0 – 15,000mg/L O2 | ||
High Range, Dichromate closed reflux Method, 150 Tests | CODH150 | Digestion Tube | 0 – 15,000mg/L O2 | AQUAfast Digestion Tubes, Range: 0 to 15000 mg/L O2, COD High Range* | |
Copper | Free & Total, Biquinoline, 50 tests | AC2029 | Tablet | 0.05 – 5mg/L | |
Free, Bicinchoninate, 100 tests | AC4P29 | Powder | 0.05 – 5mg/L | ||
Cyanide | Isonicotinic-Barbituric Acid Method, 30 tests | AC4006 | Ampoule | 0.04 – 0.4mg/L | |
Fluoride | SPADNS Kit Method, 50 tests | AC2009 | Liquid | 0.05 – 2 mg/L | |
Hydrazine | 4-(Dimethyl-amino)-Benzaldehyde Method, 30 tests | AC2030 | Powder | 0.05 – 0.5 mg/L | |
Iron | (II & III), PPST Method, 100 tests | AC2078 | Tablet | 0.02 – 1 mg/L | |
Ferro, 1,10-Phenanthroline Method, 100 tests | AC4P78 | Powder | 0.02 – 3 mg/L | ||
Total & Soluble, Phenanthroline Method, 30 tests | AC4078 | Ampoule | 0.2 – 6 mg/L | ||
Total, TPTZ Method, 100 tests | AC4P79 | Powder | 0.02 – 1.8 mg/L | ||
Manganese | Formaldoxime Method, 50 tests | AC2055 | Tablet | 0.2 – 4 mg/L | |
High Range, Periodate Oxidation Method, 100 tests | AC4P55 | Powder | 0.1 – 18 mg/L | ||
Periodate Method, 30 tests | AC4055 | Ampoule | 2 – 30 mg/L | ||
Molybdate / Molybdenum | Mercaptoacetic Acid Method, 100 tests | AC4P42 | Powder | 0.5 – 66 mg/L | |
Nitrate as Nitrogen (N) | Cadmium Reduction Method, 30 tests | AC4004 | Ampoule | 0.2 – 1.5 mg/L | |
Cadmium Reduction Method, 30 tests | AC4005 | Ampoule | 2.0 – 7.50 mg/L | ||
Zinc Reduction Method, 50 tests | AC2007 | Tablet | 0.08 – 1 mg/L | ||
Cadmium Reduction Method, 30 tests | AC4007 | Ampoule | 5 – 50 mg/L | ||
Diazotization (NED) Method | AC4P46 | Powder | 0.01 – 0.3 mg/L | ||
Diazotization (NED) Method | AC4046 | Tablet | 0.08 – 1 mg/L | ||
Diazotization (NED) Method | AC2046 | Tablet | 0.01 – 0.5 mg/L | ||
Ozone | DPD Method, 30 tests | AC4048 | Ampoule | 0.2 – 5 pH | |
pH | Phenol Red Method, 100 tests | AC2001 | Tablet | 6.5 – 8.4 pH | |
Phosphate | Phosphate, Ortho, Phosphomolybdenum/Ascorbic Acid Method, 100 tests | AC4P95 | Powder
| 0.06 – 2.5 mg/L | |
Phosphate, Ortho, Phosphomolybdic Acid/Ascorbic Acid Method, 50 tests | AC2095-WA | Tablet
| 0.05 – 4 mg/L | ||
Ortho, Stannous Chloride Method, 30 tests | g | Reaction Tube | 0.3 – 8 mg/L | ||
Phosphate, Ortho, Ascorbic Acid/Vanadomolybdate Method, 50 tests | AC2096 | Tablet | 1 – 80 mg/L | ||
Silica | Heteropoly Blue Method, 30 tests | AC4060 | Ampoule | 0.5 – 10 mg/L | |
Phosphate Removal for AC2060 Method, 100 tests | AC2061 | Tablet | ---- | ||
High Range, Silicomolybdate Method, 100 tests | AC4P60 | Powder | 1 – 90 mg/L | ||
Silicomolybdate, Heteropoly Blue Method, 50 tests | AC2060 | Tablet | 0.05 – 4 mg/L | ||
Sulfate | Barium Sulfate/Turbidity Method, 100 tests | AC2082 | Tablet | 5 – 100 mg/L | |
Barium Sulfate/Turbidity Method, 30 tests | AC4082 | Ampoule | 8 – 100 mg/L | ||
Barium Sulfate/Turbidity Method, 100 tests | AC4P82 | Powder | 5 – 100 mg/L | ||
Sulfide | Acid Soluble, Methylene Blue Method, 30 tests | AC4016 | Ampoule | 0.2 – 3 mg/L | |
DPD/Catalyst Method, 50 tests | AC2016 | Tablet | 0.04 – 0.5 mg/L | ||
Zinc
| Zinc, Zincon Method, 50 tests | AC2065 | Tablet | 0.02 – 1 mg/L | |
Zinc, Zincon Method, 30 pack | AC4065 | Auto-ID Ampoule | 0.3 – 3 mg/L |
*Compliant with US EPA and other global testing methods for COD in wastewater
Accessories for use with the AQUAfast AQ4000 Colorimeter
Cat. No. | Description |
|
AC2V16 | Replacement 16mm vials, 10/pack | |
AC2V24 | Replacement 24mm vials, 12/pack | |
AC3CBR | Vial cleaning brush, 5/pack | |
AQ4CBL | RS232 cable for data download and software update | |
AQ4ZER | AQUAfast Zero Kit | |
COD165 | Digestion methods thermoreactor, pre-set for 100°, 120°, 150°, 160°, and 165°C | |
CODS01 | COD standard, 1000ppm, 475mL | |
CODS10 | COD standard, 10000ppm, 475mL | |
CLSK100 | Chlorine primary standard, 1.5mg/L ampoule kit | |
AC3ROD | Crush and stir rod for tablets and AC2V24 vials |
Chemical species | Method Description | Method | Form Factor | Range | Shop |
Chlorine | |||||
Free, DPD Method, 100 tests | AC4P71 | Powder | 0.02 – 2 mg/L Cl2; 0.1 – 8 mg/L Cl2+ | ||
Free, DPD bulk powder dispenser with one vial x 250 tests | AQ250F | Powder | 0.02 – 2 mg/L Cl2 | ||
Free, DPD powder refill for AQ250F dispenser, 1 vial x 250 tests | AC71P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Free, DPD powder refill for AQ250F dispenser, 2 vials x 250 tests each | AC71P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* | |
Total, DPD Method, 100 tests | AC4P72 | Powder | 0.02 – 2 mg/L Cl2; 0.1 – 8 mg/L Cl2+ | ||
Total, Bluk DPD powder dispenser with one vial x 250 tests | AQ250T | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder dispenser with one vial x 250 count* | |
Total, DPD powder refill for AQ250T dispenser, 1 vial x 250 tests | AC72P1 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast total chlorine DPD powder refill for AQ250T dispenser* | |
Total, DPD powder refill for AQ250T dispenser, 2 vials x 250 tests each | AC72P2 | Powder | 0.02 – 2 mg/L Cl2 | AQUAfast free chlorine DPD powder refill for AQ250F dispenser* |
† Use AC2V10 short path length plastic vials and two powder packs.
*Compliant with US EPA and other global testing methods for COD in wastewater
Accessories for use with the AQUAfast AQ3170 Colorimeter
Cat. No. | Description |
|
AC2V24 | Replacement 24mm vials, 12/pack | |
AC2V10 | AQUAfast 10mm short path length plastic vials for high-level chlorine, 12/pack | |
CLSK100 | Chlorine primary standard, 1.5mg/L ampoule kit | |
CLSK200 | Chlorine secondary standards (0.0, 0.2, and 1mg/L) | |
AC3CBR | Vial cleaning brush, 5/pack |
Chemical species | Method Description | Method | Form Factor | Range | Shop |
COD | Low Range, Dichromate Digestion Method, 25 Tests | CODL00 | Digestion Tube | 0 – 150mg/L | |
Low Range, Dichromate Digestion Method, 150 Tests | CODL150 | Digestion Tube | 0 – 150mg/L O2 | ||
Mid Range, Dichromate Digestion Method, 25 Tests | CODH00 | Digestion Tube | 0 – 1,500mg/L | ||
Mid Range,Dichromate Digestion Method, 150 Tests | CODM150 | Digestion Tube | 0 – 1,500mg/L O2 | ||
High Range, Dichromate Digestion Method, 25 Tests | CODHP0 | Digestion Tube | 0 – 15,000mg/L | AQUAfast Digestion Tubes, Range: 0-15000 mg/L O2 COD High Range* | |
High Range, Dichromate Digestion Method, 150 Tests | CODH150 | Digestion Tube | 0 – 15,000mg/L O2 | AQUAfast Digestion Tubes, Range: 0 to 15000 mg/L O2, COD High Range* |
*Compliant with US EPA and other global testing methods for COD in wastewater
Accessories for use with the AQUAfast AQ3140 COD Colorimeter
Request a consultation
Get answers to your top water analysis and water purification questions and see products in action. Learn about:
· pH & Multiparameter Benchtop & Portable Meters
· Electrodes (pH Electrodes, ISE, Conductivity, DO)
· Potentiometric Titrators
· Spectrophotometers
· Water Purification Systems