Description | Catalog Number |
Estimated Lifetime |
Impurities Removed |
Effects if Not Replaced |
Ultrapure Cartridge | 09.2005 | Up to 6-12 months depending on feed water quality |
Ions | *Low resistivity/high conductivity in water |
0.2um Final Filter | 09.1003 | Up to 3-12 months |
Bacteria |
*Interference in analytical method *Bacteria and particles in the water *Slow dispense flow rate |
UV Lamp UV or UV/UF units only |
09.2002 | Up to 2 years |
Organics Bacteria |
*Increased TOC causing problems in analytical methods and biological methods *Bacteria in system |
50133980 | Up to 2 years |
Endotoxins |
*Cell culture growth retarded or cell death *Degradation of DNA and RNA |
|
CMX25 | N/A |
Bacteria | *Bacteria in water system *Slow dispense flow rate |
Description | Catalog Number | Estimated Llfetime * | Impurities removed | Effects if not replaced |
Smart2Pure Pro RO membrane | 50157608 | Up to 12 months | General removal of: Ions Organics Bacteria |
*Increased ion, organic and bacteria impurities in water. *Ultrapure cartridge exhausting quickly |
Ultrapure cartridge | 09.1020 | Up to 12 months | Ions | *Low resistivity/high conductivity in water *Interference in analytical methods, molecular biology and cell culture |
0.1 um filter | 50157375 | Up to 3 -12 months | Bacteria Particulates |
*Bacteria and particles in the water *Mycoplasma contamination *Slow dispense flow rate |
0.2 um filter for system and hand remote dispenser | 09.1003 | Up to 12 months | Bacteria Particulates |
*Interference in analytical method *Bacteria and particles in the water *Slow dispense flow rate |
UV Lamp | 09.1002 | When applicable -Up to 2 years | Organics Bacteria |
*Increased TOC causing problems in analytical methods and biological methods *Bacteria in system |
Ultrafilter | 50133980 | Up to 2 years |
Endotoxins Nucleases Bacteria |
*Cell culture growth retarded or cell death *Degradation of DNA and RNA |
Storage reservoir CO2 vent filter | 06.5002 | Up to 12 months | Airborne particulates CO2 and vapors |
*Contaimination of stored water cause water system to work harder |
Description | Catalog Number | Estimated Lifetime * | Impurities removed | Effects if not replaced |
RO membrane for Smart2Pure 3 LPH Pretreatment Cartridge | 09.2003 | Up to 12 months | General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. *Ultrapure cartridge exhausting quickly |
RO membrane for Smart2Pure 6 LPH Pretreatment Cartridge | 09.2006 | Up to 12 months | General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. *Ultrapure cartridge exhausting quickly |
Ultrapure cartridge | 09.1020 | Up to 12 months | Ions | *Low resistivity/high conductivity in water *Interference in analytical methods, molecular biology and cell culture |
0.2 um filter for system and hand remote dispenser | 09.1003 | Up to 3 -12 months | Bacteria Particulates |
*Interference in analytical method *Bacteria and particles in the water *Slow dispense flow rate |
UV Lamp for system UV or UV/UF units only |
09.1002 | Up to 2 years |
Organics Bacteria |
*Increased TOC causing problems in analytical methods and biological methods *Bacteria in system |
Ultrafilter (For UF or UV/UF units only) |
50133981 | Up to 2 years |
Endotoxins Nucleases Bacteria |
*Cell culture growth retarded or cell death *Degradation of DNA and RNA |
Storage reservoir vent filter | 22.0091 | Airborne particulates | *Contaimination of stored water cause water system to work harder |
Description | Catalog Number | Eestimated Lifetime * | Impurities removed | Effects if not replaced |
---|---|---|---|---|
Smart2Pure 12 LPH Pretreatment Cartridge (RO membrane) | 09.2012 | Up to 12 months | General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. *Ultrapure cartridge exhausting quickly |
Ultrapure cartridge | 09.1020 | Up to 12 months | Ions | *Low resistivity/high conductivity in water *Interference in analytical methods, molecular biology and cell culture |
0.2 um filter for system and hand remote dispenser | 09.1003 | Up to 3 -12 months | Bacteria Particulates |
*Interference in analytical method *Bacteria and particles in the water *Slow dispense flow rate |
UV Lamp for Type I system UV or UV/UF units only |
09.1002 | Up to 2 years |
Organics Bacteria |
*Increased TOC causing problems in analytical methods and biological methods *Bacteria in system |
Ultrafilter For UF or UV/UF units only | 50133981 | Up to 2 years |
Endotoxins Nucleases Bacteria |
*Cell culture growth retarded or cell death *Degradation of DNA and RNA |
Storage reservoir CO2 vent filter | 06.5002 | Up to 12 months | Airborne particulates CO2 and vapors |
*Contamination of stored water cause water system to work harder |
Description | Catalog Number |
Estimated Lifetime |
Impurities Removed |
Effects if Not Replaced |
LabTower EDI 15 RO membrane (Requires 2) |
22.0046 |
Up to 2 years |
General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. |
LabTower EDI 30 RO membrane (Requires 2) |
22.0087 |
Up to 2 years |
General removal of: |
*Increased ion, organic and bacteria impurities in water. *Ultrapure cartridge exhausting quickly |
Ultrapure Cartridge | 09.2005 | Up to 6-12 months depending on feed water quality |
Ions | *Low resistivity/high conductivity in water *Interference in analytical methods, molecular biology and cell culture |
Sterile 0.2 micron final filter for system and remote dispenser option |
09.1003 | 3 -6 months |
Bacteria Particulates |
*Interference in analytical method *Bacteria and particles in the water *Slow dispense flow rate |
09.2002 | when applicable - up to 2 years |
Organics Bacteria |
*Increased TOC causing problems in analytical methods and biological methods *Bacteria in system |
|
CO2 vent filter | 09.1003 | Up to 12 months | Airborne particulates CO2 and vapors |
*Contamination of stored water cause water system to work harder |
Description | Catalog Number | Estimated Lifetime* | Impurities Removed | Effects if Not Replaced |
---|---|---|---|---|
Ultrapure Cartridge | 09.1006 | Up to 6-12 months depending on feed water quality | Ions | *Low resistivity/high conductivity in water *Interference in analytical methods, molecular biology and cell culture |
0.2um Final Filter | 09.1003 | Up to 3 -12 months | Bacteria Particulates |
*Interference in analytical method *Bacteria and particles in the water *Slow dispense flow rate |
UV Lamp UV or UV/UF units only |
09.1002 | When applicable -Up to two years | Organics Bacteria |
*Increased TOC causing problems in analytical methods and biological methods *Bacteria in system |
Ultrafilter (For UF or UV/UF units only) |
50133981 | When applicable -Up to two years | Endotoxins Nucleases Bacteria |
*Cell culture growth retarded or cell death *Degradation of DNA and RNA |
Sterile Vent Filter - MicroPure ST units only | 22.0091 | When applicable - Up to 6-12 months |
Airborne particulates | *Contamination of stored water cause water system to work harder |
Cleaning Solution | CMX25 | N/A | Bacteria | *Bacteria in water system *Slow dispense flow rate |
Description | Catalog Number |
Estimated Lifetime |
Impurities Removed |
Effects if Not Replaced |
Ultrapure Cartridge | 09.1006 |
Up to 6-12 months depending on feed water quality |
Ions | *Low resistivity/high conductivity water |
0.2um Final Filter | 09.1003 | Up to 3-12 months |
Bacteria |
*Interference in analytical method *Bacteria and particles in the water *Slow dispense flow rate |
UV Lamp |
09.1002 |
Up to 2 years |
Organics Bacteria |
*High TOC causing problems in analytical methods and biological methods |
50133981 | Up to 2 years |
Particles Bacteria |
*Particles in water going to Ion Chromatography Instrumentation | |
Sterile Vent Filter |
22.0091 | 6-12 months |
Airborne particulates | *Contamination of stored water causing system consumables work harder |
Cleaning Solution | CMX25 | N/A | Bacteria | *Bacteria in water system *Slow dispense flow rate |
Pretreatment RO cartridge (Optional for tap water feed) |
09.2012 | 6-12 months | Ions Organics Bacteria Particles |
*Shortened Ultrapure cartridge life |
Hardness Stabilizer (Optional for tap water feed) | 06.5204 | 6-12 months | Hardness | *Shortened life of Pretreatment RO Cartridge |
Description | Catalog Number | Estimated Lifetime * | Impurities removed | Effects if not replaced |
RO membrane for Pacific TII 3, 7, 12(Requires 1) | 22.0046 | Up to 2 years | General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. *DI cartridge exhausting quickly |
RO membrane for Pacific TII 20 (Requires 2) | 22.0046 | Up to 2 years | General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. *DI cartridge exhausting quickly |
RO membrane for Pacific TII 40 (Requires 2) | 22.0087 | Up to 2 years | General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. *DI cartridge exhausting quickly |
DI Cartridge | 09.4011 | Up to 12 months | Ions | *Low resistivity/high conductivity water *Interference in analytical methods |
Pacific TII System UV Lamp | 50139226 | when applicable - up to 2 years | Bacteria | *Bacteria growth in system |
0.2 um filter for hand remote dispenser option | 09.1003 | 3 -6 months | Bacteria Particulates |
*Bacteria and particles in the water *Slow dispense flow rate |
CO2 vent filter | 06.5002 | Up to 12 months | Airborne particulates CO2 and vapors |
*Contaimination of stored water cause water system to work harder |
Description | Catalog Number |
Estimated Lifetime |
Impurities Removed |
Effects if Not Replaced |
LabTower TII 20 RO membrane (Requires 1) |
22.0046 |
Up to 2 years |
General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. |
LabTower TII 40 RO membranes (Requires 2) |
22.0087 |
Up to 2 years |
General removal of: |
*Increased ion, organic and bacteria impurities in water. *DI cartridge exhausting quickly |
LabTower TII 60 RO membrane (Requires 2 each) |
22.0046 22.0087 |
Up to 2 years |
General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. *DI cartridge exhausting quickly |
DI Canister |
02.2850-LAB |
Up to 12 months |
Ions | *Low resistivity/high conductivity water *Interference in analytical methods |
50139226 | when applicable - up to 2 years |
Bacteria |
*Bacteria growth in system | |
Sterile 0.2 micron final filter for system and remote dispenser option | 09.1003 |
Up to 12 months |
Bacteria Particulates |
*Bacteria and particles in the water *Slow dispense flow rate |
Sterile Vent Filter |
50135142 | Up to 12 months |
Airborne particulates CO2 and vapors |
*Contaimination of stored water cause water system to work harder |
0.1 micron 10" filter (Installed in LabTower TII, back white canister) | 06.5557 |
Up to 6 months |
Bacteria Particulates |
*Bacteria and particles in the water |
Description | Catalog Number | Estimated Lifetime * | Impurities removed | Interferes with lab results if not replaced: |
RO membrane for Pacific RO 3, 7, 12 (Requires 1) | 22.0046 | Up to 2 years | General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. *DI cartridge exhausting quickly |
RO membrane for Pacific TII 20 (Requires 2) | 22.0046 | Up to 2 years | General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. *DI cartridge exhausting quickly |
RO membrane for Pacific RO 40 (Requires 2) | 22.0087 | Up to 2 years | General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. *DI cartridge exhausting quickly |
Vent filter | 50135142 | Up to 12 months | Airborne particulates CO2 and vapors |
*Contamination of stored water cause water system to work harder |
Description | Catalog Number |
Estimated Lifetime |
Impurities Removed |
Effects if Not Replaced |
LabTower RO 20 RO membranes (Requires 1) |
22.0046 |
Up to 2 years |
General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. |
LabTower RO 40 RO membranes (Requires 2) |
22.0087 | Up to 2 years |
General removal of: |
*Increased ion, organic and bacteria impurities in water. *DI cartridge exhausting quickly |
LabTower RO 60 RO membrane (Requires 2) |
22.0046 22.0087 |
Up to 2 years |
General removal of: Ions Organics Bacteria Particles |
*Increased ion, organic and bacteria impurities in water. *DI cartridge exhausting quickly |
09.1003 | 3 -6 months |
Bacteria Particulates |
*Bacteria and particles in the water *Slow dispense flow rate |
|
Sterile Vent Filter |
50135142 | Up to 12 months |
Airborne particulates CO2 and vapors |
*Contamination of stored water cause water system to work harder |
Description | Catalog Number |
Estimated Lifetime |
Impurities Removed |
Effects if Not Replaced |
Tap Water Cartridge kit (4 holder Epure) | D5028 | Up to 1 year |
Ions | *Low resistivity/high conductivity in water |
Tap Water - Organic Free Cartridge kit (4 holder Epure) | D5023 | Up to 1 year |
Ions Organics |
*Low resistivity/high conductivity in water *Increased organics *Interference in analytical methods |
Pretreated Feed Cartridge kit (3 holder Epure) | D5029 | Up to 1 year |
Ions | *Low resistivity/high conductivity in water *Interference in analytical methods |
Pretreated Feed - Organic Free Cartridge kit (3 holder Epure) |
D5022 | Up to 1 year |
Ions Organics |
*Low resistivity/high conductivity in water *Increased organics *Interference in analytical methods |
D50227 | Up to 1 year |
Ions | *Low resistivity/high conductivity in water *Interference in analytical methods |
|
Pretreated Feed - Organic Free Cartridge kit (4 holder Epure) |
D50228 | Up to 1 year |
Ions Organics |
*Low resistivity/high conductivity in water *Increased organics *Interference in analytical methods |
D3750 | 3 -6 months |
Bacteria Particulates |
*Bacteria and particles in the water *Slow dispense flow rate |
|
Cleaning cartridges (3 pk) |
D50223 | 6-12 months |
Bacteria | *Bacteria in water system |
Description | Catalog Number | Estimated Lifetime* | Impurities removed | Effects if not replaced |
1 micron prefilter | D502113 | 2 x per year | Rust, sediment | *Reduced RO membrane life leading to higher impurities in water |
Hardness stabilizer | D502114 | 2 x per year | Water hardness | *Hard water deposits on membrane leading to short consumable life, higher impurities in water |
Carbon cartridge | D502115 | 2 x per year | Chlorine | *Oxidation of RO membrane leading to short consumable life, higher impurities in water |
Description | Catalog Number | Estimate Lifetime | Impurities Removed | Effects if Not Replaced |
Hardness stabilizer | 06.5452 | 6 months | Water hardness, rust, sediment | *Hard water deposits on RO membrane leading to short consumable life, higher impurities in water |
5 µm filter and activated carbon cartridge | 06.5201 | 3 - 4 months | Chlorine | *Reduced RO membrane life leading to higher impurities in water |
1 µm prefilter | 06.5101 | 4 - 6 months | Rust, sediment | *Hard water deposits on membrane leading to short consumable life, higher impurities in water |
5 µm prefilter and hardness stabilizer | 06.5204 | 4 - 6 month | Water hardness | *Oxidation of RO membrane leading to short consumable life, higher impurities in water |
Salt pellets | N/A | When pellets are gone | Water hardness | *Premature failure of EDI |