Ultrahigh resolution of proteins, monoclonal antibodies, biosimilars, and charge variants
Achieve ultrahigh resolution and high efficiency separations of proteins and glycoproteins with a pI 3–10 and molecular weight over 10,000 units. Thermo Scientific ProPac Protein LC columns have a long-standing reputation for providing excellent reproducibility and durability under a broad range of pH, temperature, and mobile phase compositions.
ProPac columns along with Thermo Scientific MAbPac and Acclaim SEC 300 columns comprise our broader portfolio that address the challenges in biopharmaceutical separations.
Unsure if you need anion or cation exchange column?
Separations are based on the accessible surface charge of the protein or glycoprotein with the column’s functional group. Unsure if you need an anion or cation exchange column? The protein’s pI can help to determine which column to use.
- If your protein pI is < 6, start with anion exchange columns. You may need to try both SAX and WAX options to determine which offers the best resolution.
- If your pI is > 6, start with cation exchange columns. The ProPac Elite is our newest innovation providing the ultrahigh resolution, speed and efficiently along with the ability to use pH gradients as well as salt gradients. If you are just starting to develop your method, consider starting with this column.
Recommended Ion Exchange Columns by Type | |||||
---|---|---|---|---|---|
Column Type | Strong anion exchange (SAX) columns | Weak anion exchange (WAX) columns | Weak cation exchange (WCX) columns | Strong cation exchange (SCX) columns | |
Column | ProPac SAX-10 | ProPac WAX-10 | ProPac Elite WCX 5μm | ProPac WCX-10 | MAbPac SCX |
Functional group | Quaternary ammonium | Tertiary amine | Carboxylic acid | Sulfonic acid | |
Sample pI | Typically for protein pI is < 6 | Typically for protein pI is > 6 | |||
Notes | Based on WCX-10 column Ultrahigh resolution Faster, more efficient, highly reproducible | Long standing gold-standard column | Strong Cation Exchange columns offer an alternate selectivity to Weak Cation Exchange columns | ||
Gradient | Use salt gradient | WAX will buffer your phase more than SAX | Use salt or pH gradients* | Use salt gradient | Use salt or pH gradients |
* Using our CX-1 pH Gradient Buffers
Innovation inside ProPac Ion Exchange Columns
- Resolves variants that differ by as little as one amino acid.
- Eliminates hydrophobic interactions, resulting in very efficient peaks.
- Nonporous 5 or 10µm particles are solvent-compatible ethylvinylbenzene cross-linked with 55% divinylbenzene polymer (DVB) substrate.
- Resin is covered with a highly hydrophilic, neutral polymer, to minimize nonspecific interactions between the surface and the biopolymer.
- A controlled polymer chain is grafted on the hydrophilic layer to introduce the ion exchange functionality containing the anion- or cation-exchange groups that impart selectivity and reproducible capacity.
- The selectivity differences between the various resin types provide flexibility in maximizing the resolution of closely related proteins.
Use for
- Characterization and quality control assessment of monoclonal antibodies and other proteins.
- Exceptionally high resolution and efficiency for separations of protein variants such as sequence variants, truncation variants, phosphorylation variants sialylation variants, deamidation variants, and other variants.
ProPac & MAbPac hydrophobic interaction chromatography (HIC) columns
With many opportunities for post translational modifications (PTMs), it is often necessary to employ multiple column supports to detect, characterize, and quantify all structural variants and modifications and to monitor product stability.
Separates proteins, peptides, and other biomolecules by their degree of hydrophobicity
HIC columns separate proteins and mAb molecules in order of increasing hydrophobicity under non-denaturing conditions. Analytes bind to the weakly hydrophobic stationary phase in the presence of high salt concentration and elute off the column as the salt concentration decreases.
Nondenaturing
In contrast to reversed phase liquid chromatography, HIC typically preserves the biological activity of the protein, which is useful for downstream functional analysis such as binding and cell-based potency assays.
- Ideal for separation of protein/peptides including complex mixtures
- Non-denaturing conditions to preserve biological activity
- Excellent resolution and high efficiencies
- High capacity column
- Compatible with organic solvents and can be used in separations of very hydrophobic proteins
- Broad range of applications
Also see our Thermo Scientific MAbPac HIC columns
MAbPac HIC-10 LC Column | MAbPac HIC-20 LC Columns | MAbPac HIC-Butyl LC Columns |
---|---|---|
|
|
|
About ProPac & MAbPac biopharma HPLC columns
The biotechnology and biopharmaceutical industry has an extensive development pipeline for protein and monoclonal antibody (mAb) therapeutics. We understand that mAbs have very complex structures, with many possible site-specific variations that can change safety, efficacy, and stability profiles. With such potential for post translational modifications (PTMs), it is essential to detect, characterize, and quantify structural variants and modifications and to monitor product stability.
We see it as our job to develop and deliver innovative and efficient analytic tools during mAb development and production to prove safety, efficacy, and stability to regulatory agencies. Look to Thermo Scientific HPLC and LC/MS instruments and HPLC columns as your essential tools for the characterization of mAb and other protein biotherapeutics. They have been designed to address your challenges.
Thermo Scientific BioLC columns for mAbs, mAb variants, and other proteins
- ProPac ion exchange columns provide exceptionally high resolution and efficiency for separations of protein variants. These columns are capable of resolving isoforms that differ by as little as one charged residue.
- MAbPac columns, specifically designed for the separation of monoclonal antibodies, complement ProPac columns.
Analysis | Description | Columns & Buffers |
---|---|---|
Charge variant analysis | Routine charge variant profiling/screening, including lysine truncation, deamidation & acylation | |
Methionine & tryptophan oxidation | Targeted analysis of methionine and tryptophan oxidation | |
Antibody drug conjugate (ADC) analysis using MS | ADC DAR analysis/ Drug to Antibody ratio and intact mass | |
Intact mAb & fragment analysis | Light chain (LC) and heavy chain (HC) analysis Fragment (Fab and Fc) analysis scFc and F(ab’)2 analysis |
Related products
- Robust, reproducible pH gradients for a wide range of mAb charge variants
- Ready to use with existing LC columns and systems
- No need to formulate mobile phases
- Save time in method development
- Save time in method transfer to QA/QC
Featured ProPac videos
Learn how to easily produce linear pH gradients for fast and robust therapeutic protein separations pH gradient buffer kits with ion exchange columns.
Educational webinars
Learn how to optimize the challenging characterization of proteins, mAbs, biosimilars, and their charge variants using new ProPac Elite weak cation exchange column chemistry.
Biopharma community & collaboration
National Institute for Bioprocessing Research and Training (NIBRT)
Collaboration between NIBRT and Thermo Fisher Scientific is designed to enhance structural knowledge, accelerate innovations, and ensure drug safety and quality.
AppsLab Library of Analytical Applications
Unique applications compendium from NIBRT and Thermo Fisher Scientific focused on simplified, faster methods that deliver highly informative characterization data.
Visit Biopharma Characterization Resource Center
Learn more about the innovative technologies for charge variant analysis.
Receive updates
Keep up to date with our latest scientific content and promotions.
Find interactive tools and calculators, guides to select the right products, equivalent product finders, and get in contact with our consumables technical support team to answer your application questions.
Access the latest interactive version of our Chromatography Consumables & Columns Catalog. Our enhanced online version features easier access to product information, key application notes and brand-new selector tools.
Discover live and on-demand webinars that enable you to improve productivity, maintain compliance, and learn about the constantly evolving scientific landscape.