Annexin V staining is a common method used for identifying and analyzing apoptotic cells, providing valuable insights into the underlaying mechanisms of programmed cell death. Thermo Fisher Scientific offers high-quality annexin V fluorescent conjugates, available as stand-alone reagents or in convenient kits for flow cytometry or imaging suspension cells. Our Annexin V products are conjugated to Alexa Fluor and eFluor dyes, helping ensure brighter signals and compatibility with a wide range of laser lines.
What is annexin V staining?
The human vascular anticoagulant annexin V is a 35–36 kDa, Ca2+-dependent phospholipid-binding protein that has a high affinity for the anionic phospholipid phosphatidylserine (PS). In normal healthy cells, PS is located on the cytoplasmic surface of the plasma membrane. However, during apoptosis, the plasma membrane undergoes structural changes that include translocation of PS from the inner to the outer leaflet (extracellular side) of the plasma membrane.
It has been reported that the translocated phosphatidylserine on the outer surface of the cell marks the cell for recognition and phagocytosis by macrophages (1). Fluorescent conjugates of annexin V are commonly used to identify apoptotic cells by binding to PS (Figure 1).
Annexin V conjugates for apoptosis detection
Annexin V conjugates provide quick and reliable detection methods for studying the externalization of phosphatidylserine, during apoptosis. The difference in fluorescence intensity between apoptotic and nonapoptotic cells stained with our fluorescent annexin V conjugates, as measured by flow cytometry, is typically about 100-fold.
Experimental conditions for annexin V staining
Annexin V staining to detect apoptotic cells can only be done on live cells and tissue. If samples are to be fixed post-staining, there are specific conditions required to achieve transient retention of signal. These include use of an alcohol-free, aldehyde-based fixation method, use of buffers containing Ca2+ and avoidance of surfactants/detergents. For your convenience, we also offer a concentrated annexin-binding buffer that facilitates the binding of annexin V to phosphatidylserine in apoptosis assays.
Avoiding false positives
It should be noted that there is a risk of false positives when staining with annexin V conjugates. Compromised plasma membranes of dead cells provide a path for annexin V protein to pass through to the interior of the cell where it can bind PS in the inner leaflet. We recommend using a live cell-impermeant stain in combination with annexin V conjugates. This combination allows for the separation of apoptotic cells from dead cells. While cells positive for both probes may indicate late stage apoptosis, annexin V staining in this population may be due to inner leaflet PS binding and therefore may not be reliably deemed apoptotic. In this combination, cells that are only annexin V-positive and therefore have intact plasma membranes, are demonstrably apoptotic. We offer a range of kits that include an annexin V conjugate and a compatible live cell-impermeant stain. These kits have been optimized for flow cytometry.
The selection guide below gives an overview of the stand-alone annexin V conjugates available as well as the required binding buffer.
Microscopy | Flow cytometry | |||
Annexin V conjugate | Ex/Em (nm) | Common emission filters | Laser | Common emission filters |
---|---|---|---|---|
Alexa Fluor 350 | 346/442 | DAPI | UV | 450/40 nm |
Pacific Blue | 410/455 | NA | 405/7 nm | 450/50 nm |
Alexa Fluor 488 | 490/525 | FITC | 488 nm | 530/30 nm |
FITC | 490/525 | FITC | 488 nm | 530/30 nm |
PE | 565/578 | TRITC | 488 nm 532 nm 561 nm | 585/42 nm |
Alexa Fluor 555 | 555/580 | TRITC | 532 nm 561 nm | 575/26 nm |
Alexa Fluor 568 | 578/603 | Texas Red | 532 nm 561 nm | 610/20 nm |
Alexa Fluor 594 | 590/617 | Texas Red | 532 nm | 630/20 nm |
Alexa Fluor 647 | 650/665 | Cy5 | 633-637 nm | 661/8 nm |
APC | 650/660 | Cy5 | 633-637 nm | 661/8 nm |
Alexa Fluor 680 | 679/702 | Cy5.5 | 633-637 nm | 720/30 nm |
Biotin-X | NA | NA | NA | NA |
Required buffer | ||||
Annexin Binding Buffer (5x) | Facilitates the binding of annexin V to phosphatidylserine for apoptosis assays in flow cytometry |
Alexa Fluor 488 Annexin V staining in flow cytometry experiment
Annexin V stains can be used to evaluate potential apoptosis-inducing drug treatments in live cell. Live cells treated with apoptosis-inducing drugs (i.e. camptothecin) will demonstrate an increase in apoptotic cells (Figure 2, bottom right).
Figure 2. Jurkat cells (T cell leukemia, human) treated with 10 μM camptothecin for 4 hours (right panel) or untreated (as control, left panel). Cells were then treated with Annexin V, Alexa Fluor 488 conjugate to identify apoptotic cells and with propidium iodide to identify dead cells, followed by flow cytometric analysis. Note that the camptothecin-treated cells (right panel) have a higher percentage of apoptotic cells (indicated by an “A”) than the basal level of apoptosis seen in the control cells (left panel). V = viable cells, D = dead cells.
The selection guide below gives an overview of the assay kits that contain annexin V conjugates. Learn more about Annexin V assay kits below.
Product | Annexin V conjugate (ex/em maxima) | Dead cell stain (ex/em maxima) | Additional reagents in kit | Size |
---|---|---|---|---|
Annexin V, Alexa Fluor 488 (499/521 nm) | PI (535/617 nm) | Annexin binding buffer (5x) | 250 assays | |
50 assays | ||||
Annexin V, Fluorescein (494/518 nm) | PI (535/617 nm) | 50 assays | ||
Annexin V, APC (650/660 nm) | SYTOX Green (503/524 nm) | 50 assays | ||
Annexin V, RPE (488/575 nm) | SYTOX Green (503/524 nm) | 50 assays | ||
Annexin V Apoptosis Detection Kits | Annexin V, APC (650/660) | PI (535/617) | Annexin binding buffer (10x) | 200 assays |
50 assays | ||||
Annexin V, FITC (488/520) | PI (535/617) | 200 assays | ||
50 assays | ||||
Annexin V, PE | 7-ADD (546/647 nm) | 200 assays | ||
50 assays | ||||
Annexin V, eFluor 450 (405/450 nm) | 7-AAD (546/647 nm) | 200 assays | ||
50 assays | ||||
Annexin V, RPE-Cyanine7 (488/767 nm) | — | 200 assays | ||
50 assays | ||||
Annexin V, PerCP-eFluor 710 (482/710 nm) | — | 200 assays | ||
50 assays | ||||
Pacific Blue Annexin V/SYTOX AADvanced Apoptosis Kit | Annexin V, Pacific Blue (415/455 nm) | SYTOX AADvanced (546/647 nm) | Annexin binding buffer (5x) | 50 assays |
Metabolic Activity Dead Cell Apoptosis Kit | Annexin V, APC (650/660 nm) | SYTOX Green (503/524 nm | • Annexin binding buffer (5x) • C12-resazurin (571/585 nm) | 50 assays |
Mitochondrial Membrane Potential Apoptosis Kit | Annexin V, Alexa Fluor 488 (499/521 nm) | none | • MitoTracker Red (CMXRos) • Annexin binding buffer (5x) • DMSO | 50 assays |
Single-channel Dead Cell Apoptosis Kit | Annexin V, Alexa Fluor 488 (499/521 nm) | SYTOX Green (503/524 nm) | Annexin binding buffer (5x) | 50 assays |
Annexin V Apoptosis Detection Kits
During early stages of apoptosis, PS located on the exterior of cells will stain with Annexin V. The intact plasma membrane prevents other dyes such as propidium iodide (PI), 7-AAD, or fixable viability dyes from entering the cell. During late stages of apoptosis, the cell membrane loses integrity and allows annexin V to stain interior PS. The use of additional viability dyes can differentiate between late-stage apoptotic cells and necrotic cells (Figure 3, 4).
Figure 3. Annexin V staining with 7-AAD viability dye. Mouse thymocytes were prepared as a single cell suspension and incubated overnight at 37°C in medium. Cells were harvested and stained with Annexin V eFluor™ 450 and 7-AAD Viability Staining Solution. Early-stage apoptotic cells are seen in the upper left (annexin V positive, viability dye negative). Late-stage apoptotic and necrotic cells are seen in the upper right (annexin V positive, viability dye positive).
Figure 4. Annexin V staining with fixability viability dye eFluor 780. Mouse thymocytes were prepared as a single cell suspension and incubated overnight at 37°C in medium to induce apoptosis. Cells were harvested and stained using the Annexin V Apoptosis Detection Set PE-Cyanine7 and Fixable Viability Dye eFluor™ 780. Early-stage apoptotic cells are seen in the upper left (annexin V positive, viability dye negative). Late-stage apoptotic and necrotic cells are seen in the upper right (annexin V positive, viability dye positive).
Annexin V/SYTOX AADvanced Apoptosis Kit
Externalized phosphatidylserine in apoptotic cells is detected using recombinant annexin V conjugated to Pacific Blue (violet-fluorescence) while dead cells are detected using SYTOX AADvanced. Populations can be distinguished by using a flow cytometer with a 405 nm and 488 nm laser lines. A dual parameter plot will show apoptotic cells as violet fluorescence, dead/necrotic cells will be shown as dual red and violet fluorescence, and live cells will be show little to no fluorescence (Figure 5).
Metabolic Activity Dead Cell Apoptosis Kit
Annexin V assays are available to distinguish live (C12 resazurin - Dodecylresorufin), apoptotic (Annexin V), and late apoptotic (SYTOX Green nucleic acid stain) cells (Figure 6). Nonfluorescent C12-resazurin is reduced to C12-resorufin by live cells and is proportional to the number of cells present. Populations can be distinguished by using a flow cytometer with 488 nm and 633 nm laser lines.
Figure 6. Flow cytometric analysis of Jurkat cells using the Metabolic Activity/Annexin V/Dead Cell Apoptosis Kit. Jurkat human T-cell leukemia cells were first exposed to either 10 µM camptothecin or 2 mM hydrogen peroxide for 4 hours at 37°C, 5% CO2. The cells were then combined, treated with the reagents in the kit and analyzed by flow cytometry. (A) The SYTOX Green fluorescence versus allophycocyanin (APC) annexin fluorescence dot plot shows resolution of live, apoptotic and dead cell populations. The cell populations can be evaluated for metabolic activity using (B) the dodecylresorufin fluorescence versus SYTOX Green fluorescence dot plot and (C) the dodecylresorufin fluorescence versus allophycocyanin fluorescence dot plot.
Alternatives to annexin V staining
There are some situations where the optimal method for the detection of apoptosis is not annexin V staining. These include assays where cells are sensitive to the high calcium concentrations required for annexin V binding, or assays where phosphatidylserine detection on adherent cells is adversely affected by trypsinization, and assays where washing of samples is prohibitive. We provide unique flow cytometry assays to measure membrane changes under conditions where annexin V binding is problematic.
Learn about additional apoptosis assays for imaging, microplates, or high-content analysis
When the use of calcium containing buffers isn’t an option
- No special buffers or wash steps required
- Simple, 5-minute staining protocol for flow cytometry
- Compatible with other blue-excited apoptotic stains
- Accurate apoptotic analysis on trypsinized cells
The Violet Ratiometric Membrane Asymmetry Probe⁄Dead Cell Apoptosis Kit provides an easy, efficient method for the detection of apoptosis with dead cell discrimination using a violet laser flow cytometer. Unlike annexin-based assays, this assay does not require special buffers or wash steps, and it is less susceptible to the cell membrane damage commonly found during the physical or chemical removal steps when assaying adherent cells, therefore providing better data quality. The Violet Ratiometric Membrane Asymmetry Probe (F2N123S) works well on adherent and suspension cells and correlates with other indicators of apoptosis, such as caspase detection and changes in mitochondrial membrane potential.
Product | Laser | Ex/Em | Apoptotic cell stain | Dead cell stain | Cat. No. |
---|---|---|---|---|---|
Violet Ratiometric Membrane Asymmetry Probe/Dead Cell Apoptosis Kit | 405 and 488 nm | 405/585 (live), 405/530 (apoptotic), 546/647 (dead) | F2N12S | SYTOX AADvanced | A35137 |
Membrane Permeability/Dead Cell Apoptosis Kit | 405 and 488 nm | 434/456 nm (apoptotic) 546/647 nm (dead) | PO-PRO-1 | 7-AAD | V35123 |
The dye exhibits an excited-state intramolecular proton transfer (ESIPT) reaction resulting in a dual fluorescence with two emission bands corresponding to 530 nm and 585 nm, producing a two-color ratiometric response to variations in surface charge. The F2N12S probe is combined with SYTOX AADvanced dead cell stain, which is capable of passing through the cell membrane only in late apoptotic or necrotic cells allowing discrimination form early apoptotic cells (Figure 7). The Violet Ratiometric Membrane Asymmetry Probe⁄Dead Cell Apoptosis Kit can also be paired with MitoProbe DilC1(5) for analysis of apoptosis and viability (Figure 8).
Figure 7. Violet Ratiometric Membrane Asymmetry Probe for apoptosis detection. Jurkat cells (T-cell leukemia, human) were treated with 10 μM camptothecin for four hours (panels B and D) or left untreated as a control (panels A and C). Samples were analyzed on a flow cytometer with 405 nm excitation using 585 nm and 530 nm bandpass filters for F2N12S, and 488 nm excitation for SYTOX AADvanced dead cell stain using a 695 nm bandpass filter. Living cells can be discriminated from apoptotic and dead cells by the relative intensities of the two emission bands from F2N12S (A and B). In panels C and D, SYTOX AADvanced dead cell stain fluorescence is plotted against a derived ratio parameter from the two emission bands (585/530 nm) of F2N12S. A = apoptotic cells, L = live cells, D = dead cells.
Figure 8. Violet Ratiometric Membrane Asymmetry Probe/Dead Cell Apoptosis Kit for apoptosis detection. Control (top row) and 4-hour camptothecin-treated (bottom row) Jurkat cells were stained with 1 µM SYTOX® AADvanced™ Dead Cell Stain, 200 nM F2N12S, and 50 nM MitoProbe™ DiIC1(5). Dead cells were first excluded (histograms) by gating live cells (those that have lower SYTOX® AADvanced™ fluorescence, indicated by bars). Bivariant density plots show a two-parameter apoptosis assay for mitochondrial membrane potential loss (decreased DiIC1(5) fluorescence) and breakdown of membrane asymmetry (smaller F2N12S 585/530 nm fluorescence ratio). The A, L, and D labels on the graphs indicate apoptotic, live, and dead cells, respectively.
What is annexin V staining?
The human vascular anticoagulant annexin V is a 35–36 kDa, Ca2+-dependent phospholipid-binding protein that has a high affinity for the anionic phospholipid phosphatidylserine (PS). In normal healthy cells, PS is located on the cytoplasmic surface of the plasma membrane. However, during apoptosis, the plasma membrane undergoes structural changes that include translocation of PS from the inner to the outer leaflet (extracellular side) of the plasma membrane.
It has been reported that the translocated phosphatidylserine on the outer surface of the cell marks the cell for recognition and phagocytosis by macrophages (1). Fluorescent conjugates of annexin V are commonly used to identify apoptotic cells by binding to PS (Figure 1).
Annexin V conjugates for apoptosis detection
Annexin V conjugates provide quick and reliable detection methods for studying the externalization of phosphatidylserine, during apoptosis. The difference in fluorescence intensity between apoptotic and nonapoptotic cells stained with our fluorescent annexin V conjugates, as measured by flow cytometry, is typically about 100-fold.
Experimental conditions for annexin V staining
Annexin V staining to detect apoptotic cells can only be done on live cells and tissue. If samples are to be fixed post-staining, there are specific conditions required to achieve transient retention of signal. These include use of an alcohol-free, aldehyde-based fixation method, use of buffers containing Ca2+ and avoidance of surfactants/detergents. For your convenience, we also offer a concentrated annexin-binding buffer that facilitates the binding of annexin V to phosphatidylserine in apoptosis assays.
Avoiding false positives
It should be noted that there is a risk of false positives when staining with annexin V conjugates. Compromised plasma membranes of dead cells provide a path for annexin V protein to pass through to the interior of the cell where it can bind PS in the inner leaflet. We recommend using a live cell-impermeant stain in combination with annexin V conjugates. This combination allows for the separation of apoptotic cells from dead cells. While cells positive for both probes may indicate late stage apoptosis, annexin V staining in this population may be due to inner leaflet PS binding and therefore may not be reliably deemed apoptotic. In this combination, cells that are only annexin V-positive and therefore have intact plasma membranes, are demonstrably apoptotic. We offer a range of kits that include an annexin V conjugate and a compatible live cell-impermeant stain. These kits have been optimized for flow cytometry.
The selection guide below gives an overview of the stand-alone annexin V conjugates available as well as the required binding buffer.
Microscopy | Flow cytometry | |||
Annexin V conjugate | Ex/Em (nm) | Common emission filters | Laser | Common emission filters |
---|---|---|---|---|
Alexa Fluor 350 | 346/442 | DAPI | UV | 450/40 nm |
Pacific Blue | 410/455 | NA | 405/7 nm | 450/50 nm |
Alexa Fluor 488 | 490/525 | FITC | 488 nm | 530/30 nm |
FITC | 490/525 | FITC | 488 nm | 530/30 nm |
PE | 565/578 | TRITC | 488 nm 532 nm 561 nm | 585/42 nm |
Alexa Fluor 555 | 555/580 | TRITC | 532 nm 561 nm | 575/26 nm |
Alexa Fluor 568 | 578/603 | Texas Red | 532 nm 561 nm | 610/20 nm |
Alexa Fluor 594 | 590/617 | Texas Red | 532 nm | 630/20 nm |
Alexa Fluor 647 | 650/665 | Cy5 | 633-637 nm | 661/8 nm |
APC | 650/660 | Cy5 | 633-637 nm | 661/8 nm |
Alexa Fluor 680 | 679/702 | Cy5.5 | 633-637 nm | 720/30 nm |
Biotin-X | NA | NA | NA | NA |
Required buffer | ||||
Annexin Binding Buffer (5x) | Facilitates the binding of annexin V to phosphatidylserine for apoptosis assays in flow cytometry |
Alexa Fluor 488 Annexin V staining in flow cytometry experiment
Annexin V stains can be used to evaluate potential apoptosis-inducing drug treatments in live cell. Live cells treated with apoptosis-inducing drugs (i.e. camptothecin) will demonstrate an increase in apoptotic cells (Figure 2, bottom right).
Figure 2. Jurkat cells (T cell leukemia, human) treated with 10 μM camptothecin for 4 hours (right panel) or untreated (as control, left panel). Cells were then treated with Annexin V, Alexa Fluor 488 conjugate to identify apoptotic cells and with propidium iodide to identify dead cells, followed by flow cytometric analysis. Note that the camptothecin-treated cells (right panel) have a higher percentage of apoptotic cells (indicated by an “A”) than the basal level of apoptosis seen in the control cells (left panel). V = viable cells, D = dead cells.
The selection guide below gives an overview of the assay kits that contain annexin V conjugates. Learn more about Annexin V assay kits below.
Product | Annexin V conjugate (ex/em maxima) | Dead cell stain (ex/em maxima) | Additional reagents in kit | Size |
---|---|---|---|---|
Annexin V, Alexa Fluor 488 (499/521 nm) | PI (535/617 nm) | Annexin binding buffer (5x) | 250 assays | |
50 assays | ||||
Annexin V, Fluorescein (494/518 nm) | PI (535/617 nm) | 50 assays | ||
Annexin V, APC (650/660 nm) | SYTOX Green (503/524 nm) | 50 assays | ||
Annexin V, RPE (488/575 nm) | SYTOX Green (503/524 nm) | 50 assays | ||
Annexin V Apoptosis Detection Kits | Annexin V, APC (650/660) | PI (535/617) | Annexin binding buffer (10x) | 200 assays |
50 assays | ||||
Annexin V, FITC (488/520) | PI (535/617) | 200 assays | ||
50 assays | ||||
Annexin V, PE | 7-ADD (546/647 nm) | 200 assays | ||
50 assays | ||||
Annexin V, eFluor 450 (405/450 nm) | 7-AAD (546/647 nm) | 200 assays | ||
50 assays | ||||
Annexin V, RPE-Cyanine7 (488/767 nm) | — | 200 assays | ||
50 assays | ||||
Annexin V, PerCP-eFluor 710 (482/710 nm) | — | 200 assays | ||
50 assays | ||||
Pacific Blue Annexin V/SYTOX AADvanced Apoptosis Kit | Annexin V, Pacific Blue (415/455 nm) | SYTOX AADvanced (546/647 nm) | Annexin binding buffer (5x) | 50 assays |
Metabolic Activity Dead Cell Apoptosis Kit | Annexin V, APC (650/660 nm) | SYTOX Green (503/524 nm | • Annexin binding buffer (5x) • C12-resazurin (571/585 nm) | 50 assays |
Mitochondrial Membrane Potential Apoptosis Kit | Annexin V, Alexa Fluor 488 (499/521 nm) | none | • MitoTracker Red (CMXRos) • Annexin binding buffer (5x) • DMSO | 50 assays |
Single-channel Dead Cell Apoptosis Kit | Annexin V, Alexa Fluor 488 (499/521 nm) | SYTOX Green (503/524 nm) | Annexin binding buffer (5x) | 50 assays |
Annexin V Apoptosis Detection Kits
During early stages of apoptosis, PS located on the exterior of cells will stain with Annexin V. The intact plasma membrane prevents other dyes such as propidium iodide (PI), 7-AAD, or fixable viability dyes from entering the cell. During late stages of apoptosis, the cell membrane loses integrity and allows annexin V to stain interior PS. The use of additional viability dyes can differentiate between late-stage apoptotic cells and necrotic cells (Figure 3, 4).
Figure 3. Annexin V staining with 7-AAD viability dye. Mouse thymocytes were prepared as a single cell suspension and incubated overnight at 37°C in medium. Cells were harvested and stained with Annexin V eFluor™ 450 and 7-AAD Viability Staining Solution. Early-stage apoptotic cells are seen in the upper left (annexin V positive, viability dye negative). Late-stage apoptotic and necrotic cells are seen in the upper right (annexin V positive, viability dye positive).
Figure 4. Annexin V staining with fixability viability dye eFluor 780. Mouse thymocytes were prepared as a single cell suspension and incubated overnight at 37°C in medium to induce apoptosis. Cells were harvested and stained using the Annexin V Apoptosis Detection Set PE-Cyanine7 and Fixable Viability Dye eFluor™ 780. Early-stage apoptotic cells are seen in the upper left (annexin V positive, viability dye negative). Late-stage apoptotic and necrotic cells are seen in the upper right (annexin V positive, viability dye positive).
Annexin V/SYTOX AADvanced Apoptosis Kit
Externalized phosphatidylserine in apoptotic cells is detected using recombinant annexin V conjugated to Pacific Blue (violet-fluorescence) while dead cells are detected using SYTOX AADvanced. Populations can be distinguished by using a flow cytometer with a 405 nm and 488 nm laser lines. A dual parameter plot will show apoptotic cells as violet fluorescence, dead/necrotic cells will be shown as dual red and violet fluorescence, and live cells will be show little to no fluorescence (Figure 5).
Metabolic Activity Dead Cell Apoptosis Kit
Annexin V assays are available to distinguish live (C12 resazurin - Dodecylresorufin), apoptotic (Annexin V), and late apoptotic (SYTOX Green nucleic acid stain) cells (Figure 6). Nonfluorescent C12-resazurin is reduced to C12-resorufin by live cells and is proportional to the number of cells present. Populations can be distinguished by using a flow cytometer with 488 nm and 633 nm laser lines.
Figure 6. Flow cytometric analysis of Jurkat cells using the Metabolic Activity/Annexin V/Dead Cell Apoptosis Kit. Jurkat human T-cell leukemia cells were first exposed to either 10 µM camptothecin or 2 mM hydrogen peroxide for 4 hours at 37°C, 5% CO2. The cells were then combined, treated with the reagents in the kit and analyzed by flow cytometry. (A) The SYTOX Green fluorescence versus allophycocyanin (APC) annexin fluorescence dot plot shows resolution of live, apoptotic and dead cell populations. The cell populations can be evaluated for metabolic activity using (B) the dodecylresorufin fluorescence versus SYTOX Green fluorescence dot plot and (C) the dodecylresorufin fluorescence versus allophycocyanin fluorescence dot plot.
Alternatives to annexin V staining
There are some situations where the optimal method for the detection of apoptosis is not annexin V staining. These include assays where cells are sensitive to the high calcium concentrations required for annexin V binding, or assays where phosphatidylserine detection on adherent cells is adversely affected by trypsinization, and assays where washing of samples is prohibitive. We provide unique flow cytometry assays to measure membrane changes under conditions where annexin V binding is problematic.
Learn about additional apoptosis assays for imaging, microplates, or high-content analysis
When the use of calcium containing buffers isn’t an option
- No special buffers or wash steps required
- Simple, 5-minute staining protocol for flow cytometry
- Compatible with other blue-excited apoptotic stains
- Accurate apoptotic analysis on trypsinized cells
The Violet Ratiometric Membrane Asymmetry Probe⁄Dead Cell Apoptosis Kit provides an easy, efficient method for the detection of apoptosis with dead cell discrimination using a violet laser flow cytometer. Unlike annexin-based assays, this assay does not require special buffers or wash steps, and it is less susceptible to the cell membrane damage commonly found during the physical or chemical removal steps when assaying adherent cells, therefore providing better data quality. The Violet Ratiometric Membrane Asymmetry Probe (F2N123S) works well on adherent and suspension cells and correlates with other indicators of apoptosis, such as caspase detection and changes in mitochondrial membrane potential.
Product | Laser | Ex/Em | Apoptotic cell stain | Dead cell stain | Cat. No. |
---|---|---|---|---|---|
Violet Ratiometric Membrane Asymmetry Probe/Dead Cell Apoptosis Kit | 405 and 488 nm | 405/585 (live), 405/530 (apoptotic), 546/647 (dead) | F2N12S | SYTOX AADvanced | A35137 |
Membrane Permeability/Dead Cell Apoptosis Kit | 405 and 488 nm | 434/456 nm (apoptotic) 546/647 nm (dead) | PO-PRO-1 | 7-AAD | V35123 |
The dye exhibits an excited-state intramolecular proton transfer (ESIPT) reaction resulting in a dual fluorescence with two emission bands corresponding to 530 nm and 585 nm, producing a two-color ratiometric response to variations in surface charge. The F2N12S probe is combined with SYTOX AADvanced dead cell stain, which is capable of passing through the cell membrane only in late apoptotic or necrotic cells allowing discrimination form early apoptotic cells (Figure 7). The Violet Ratiometric Membrane Asymmetry Probe⁄Dead Cell Apoptosis Kit can also be paired with MitoProbe DilC1(5) for analysis of apoptosis and viability (Figure 8).
Figure 7. Violet Ratiometric Membrane Asymmetry Probe for apoptosis detection. Jurkat cells (T-cell leukemia, human) were treated with 10 μM camptothecin for four hours (panels B and D) or left untreated as a control (panels A and C). Samples were analyzed on a flow cytometer with 405 nm excitation using 585 nm and 530 nm bandpass filters for F2N12S, and 488 nm excitation for SYTOX AADvanced dead cell stain using a 695 nm bandpass filter. Living cells can be discriminated from apoptotic and dead cells by the relative intensities of the two emission bands from F2N12S (A and B). In panels C and D, SYTOX AADvanced dead cell stain fluorescence is plotted against a derived ratio parameter from the two emission bands (585/530 nm) of F2N12S. A = apoptotic cells, L = live cells, D = dead cells.
Figure 8. Violet Ratiometric Membrane Asymmetry Probe/Dead Cell Apoptosis Kit for apoptosis detection. Control (top row) and 4-hour camptothecin-treated (bottom row) Jurkat cells were stained with 1 µM SYTOX® AADvanced™ Dead Cell Stain, 200 nM F2N12S, and 50 nM MitoProbe™ DiIC1(5). Dead cells were first excluded (histograms) by gating live cells (those that have lower SYTOX® AADvanced™ fluorescence, indicated by bars). Bivariant density plots show a two-parameter apoptosis assay for mitochondrial membrane potential loss (decreased DiIC1(5) fluorescence) and breakdown of membrane asymmetry (smaller F2N12S 585/530 nm fluorescence ratio). The A, L, and D labels on the graphs indicate apoptotic, live, and dead cells, respectively.
Ordering information
Tools and handbooks
Fluorescence SpectraViewer
Supports all levels of experimental complexity, use the tool to compare excitation and emission spectra of fluorophores and reagents.
Flow cytometry protocols handbook
Protocols that fit your needs in flow cytometry ranging from sample preparation to numerous cell stimulation conditions, staining, immunophenotyping, and data analysis strategies.
Imaging protocol handbook
Protocols that fit your needs in imaging ranging from sample and assay preparation to staining, labeling, and data analysis strategies.
Resources
- Apoptosis Information in Cell Analysis Learning Center
Get application notes, webinars, and other useful education resources.
Molecular Probes Handbook
Support
Cell Analysis Support Center
Find technical information, tips and tricks, and answers to everyday problems.
For Research Use Only. Not for use in diagnostic procedures.