To address the HIV surveillance needs of the global community, the Applied Biosystems HIV-1 Genotyping Kit with Integrase offers broad genotyping coverage of HIV-1 Group M subtypes from extracted viral RNA from plasma and dried blood spot (DBS) samples to detect resistance to protease inhibitors, nucleoside reverse-transcriptase inhibitors, non-nucleoside reverse-transcriptase inhibitors, and integrase inhibitors.

This HIV-1 resistance kit harnesses gold-standard Sanger sequencing technology to amplify and reliably sequence the diverse and rapidly evolving HIV-1 virus.

This product employs assays for HIV-1 genotyping licensed from the U.S. Centers for Disease Control and Prevention.


HIV-1 drug resistance research testing

The new HIV-1 Genotyping Kit with Integrase covers the protease, reverse transcriptase, and integrase regions of the pol gene. 

Designed to cover the protease, reverse transcriptase, and integrase regions of the pol gene

HIV-1 amplification and sequencing reagents in one kit

Improve lot-to-lot performance, quality and timeliness of results

Request a quote

Monitoring HIV drug resistance

Webinar: HIV-1 genotyping targeting integrase

We discuss how Sanger sequencing addresses local surveillance needs in various communities and hear thoughts regarding the future trends in HIV-1 genotyping for genetic and epidemiologic surveillance.

Watch webinar

A multiplexed HIV drug resistance assay to survey HIVDR mutations in pol region

Survey HIVDR mutations with the CDC

Having an accurate and sensitive test for HIV-1 genetic variants that resist common antiretroviral therapeutics is critical for epidemiologic and genetic surveillance studies. Here, a scientist from the United States Centers for Disease Control (CDC) discusses the CDC’s experience investigating the HIV-1 Genotyping Kit with Integrase.

Watch presentation ›

The HIV-1 Genotyping Kit with Integrase features:

  • A standardized, cost-effective assay in a scalable workflow
  • A total workflow of about 20 hours for processing extracted viral RNA from EDTA plasma or DBS to results, with total hands-on time of ~4.5 hours
  • The ability to detect mutations in the protease, reverse transcriptase, and integrase regions of the HIV-1 pol gene in subtypes A, B, C, D, F, G, CRF01_AE, CRF02_AG, and CRF06_CPX
  • Easy-to-read sequencing results with software for assembly and interpretation at no additional charge
  • Compatibility with a pre-analytical solution for nucleic acid extraction from EDTA plasma and dried blood spots
Access pricing available to eligible customers. Contact us to learn more.

Contact us


Assay workflow

Nucleic acids from plasma or dried blood spot (DBS) samples are extracted. Extraction can be performed with the MagMAX Viral/Pathogen Nucleic Acid Isolation Kit for HIV-1 or other methods.

proflex

After sample processing and RNA extraction, samples undergo an initial reverse transcription + PCR, followed by a second nested PCR step for mutation targets of interest. The HIV-1 Genotyping Kit includes the RT-PCR master mix, the nested PCR master mix, and necessary positive and negative controls that allow for a simple, streamlined workflow as you move into your cleanup and sequencing steps.

3500xl

Once you confirm and clean up your targeted PCR product, the remainder of the HIV-1 Genotyping Kit with Integrase is used for cycle sequencing. Included in this kit are the forward/reverse pre-formulated sequencing mixes for the targets of interest.

Free access to Hyrax Biosciences' online platform, Exatype™, is provided with the purchase of HIV-1 Genotyping Kits. This easy-to-use application allows for:

  • Upload data upload directly to a secure web interface (sanger.exatype.com)
  • Analyzing sequencing data files, creating consensus sequences for target regions and reporting drug resistance into a user-friendly report
  • Integration with laboratory information management systems (LIMS)
  • Multiple users under a single organization license
  • Dedicated email for queries and/or information requests: sanger@hyraxbio.com
  • Easy-to-remember website for information on the Exatype Sanger HIV platform: analyzehiv.com

Nucleic acids from plasma or dried blood spot (DBS) samples are extracted. Extraction can be performed with the MagMAX Viral/Pathogen Nucleic Acid Isolation Kit for HIV-1 or other methods.

proflex

After sample processing and RNA extraction, samples undergo an initial reverse transcription + PCR, followed by a second nested PCR step for mutation targets of interest. The HIV-1 Genotyping Kit includes the RT-PCR master mix, the nested PCR master mix, and necessary positive and negative controls that allow for a simple, streamlined workflow as you move into your cleanup and sequencing steps.

3500xl

Once you confirm and clean up your targeted PCR product, the remainder of the HIV-1 Genotyping Kit with Integrase is used for cycle sequencing. Included in this kit are the forward/reverse pre-formulated sequencing mixes for the targets of interest.

Free access to Hyrax Biosciences' online platform, Exatype™, is provided with the purchase of HIV-1 Genotyping Kits. This easy-to-use application allows for:

  • Upload data upload directly to a secure web interface (sanger.exatype.com)
  • Analyzing sequencing data files, creating consensus sequences for target regions and reporting drug resistance into a user-friendly report
  • Integration with laboratory information management systems (LIMS)
  • Multiple users under a single organization license
  • Dedicated email for queries and/or information requests: sanger@hyraxbio.com
  • Easy-to-remember website for information on the Exatype Sanger HIV platform: analyzehiv.com
Data analysis and results


Ordering information

PG2740-PJT9194-COL021339-GTS-HIVDR-RUO-REMOVE-pGEM-Global-Finals

HIV-1 Genotyping Kit with Integrase

The kit contains RT-PCR and nested PCR, sequencing mixes, and controls sufficient for 48 reactions.

Order now ›

MagMAX-Viral2

MagMAX Viral/Pathogen Nucleic Acid Isolation Kit for HIV-1 

The kit contains sufficient nucleic acid extraction reagents for 100 reactions.

Order now ›

 For Research Use Only. Not for use in diagnostic procedures.

Ordering information for the Applied Biosystems HIV-1 Genotyping Kit (PR/RT only)

  • Amplification Module: A32317
  • Cycle Sequencing Module: A32318

Style Sheet for Global Design System

For Research Use Only. Not for use in diagnostic procedures.