Varioskan™ LUX multimode microplate reader
Varioskan™ LUX multimode microplate reader
Thermo Scientific™

Varioskan™ LUX multimode microplate reader

Analyze a variety of samples with five measurement technologies, including absorbance (UV-Vis), fluorescence intensity, Luminescence, AlphaScreen / AlphaLISA and TRF.
Have Questions?
Change viewbuttonViewtableView
Catalog NumberMeasurement TechnologyReading OptionsNo. of Dispensers
VLBLATD2Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreenTop and Bottom2
VL0000D0Absorbance, Fluorescence IntensityTopNone
VL0L00D0Absorbance, Fluorescence Intensity, LuminescenceTopNone
VL0L0TD0Absorbance, Fluorescence Intensity, Luminescence, Time-resolved FluorescenceTopNone
VLBL00GD0Absorbance, Fluorescence Intensity, LuminescenceTop and BottomNone
VLBL00GD1Absorbance, Fluorescence Intensity, LuminescenceTop and Bottom1
VLB000D0Absorbance, Fluorescence IntensityTop and BottomNone
VLBL00GD2Absorbance, Fluorescence Intensity, LuminescenceTop and Bottom2
VLBL00D0Absorbance, Fluorescence Intensity, LuminescenceTop and BottomNone
VLBL0TGD0Absorbance, Fluorescence Intensity, Luminescence, Time-resolved FluorescenceTop and BottomNone
VLBL0TGD1Absorbance, Fluorescence Intensity, Luminescence, Time-resolved FluorescenceTop and Bottom1
VLBLATD0Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreenTop and BottomNone
VLBL0TGD2Absorbance, Fluorescence Intensity, Luminescence, Time-resolved FluorescenceTop and Bottom2
VLBLATGD0Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreenTop and BottomNone
VLBLATGD1Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreenTop and Bottom1
VLBLATGD2Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreenTop and Bottom2
VLBL00D1Absorbance, Fluorescence Intensity, LuminescenceTop and Bottom1
VLBL0TD1Absorbance, Fluorescence Intensity, Luminescence, Time-resolved FluorescenceTop and Bottom1
VLBLATD1Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreenTop and Bottom1
VLBL00D2Absorbance, Fluorescence Intensity, LuminescenceTop and Bottom2
VLBL0TD2Absorbance, Fluorescence Intensity, Luminescence, Time-resolved FluorescenceTop and Bottom2
VLBL0TD0Absorbance, Fluorescence Intensity, Luminescence, Time-resolved FluorescenceTop and BottomNone
Catalog number VLBLATD2
Price (USD)/ Each
38,620.00
-
Add to cart
Measurement Technology:
Absorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreen
Reading Options:
Top and Bottom
No. of Dispensers:
2
Price (USD)/ Each
38,620.00
Add to cart
Varioskan™ LUX multimode microplate reader
Catalog numberVLBLATD2
Price (USD)/ Each
38,620.00
-
Add to cart

Designed for bioscience researchers with a wide variety of needs, the Thermo Scientific™ Varioskan™ LUX multimode microplate reader comes equipped with a flexible range of measurement technologies including Absorbance, Fluorescence Intensity, Luminescence, AlphaScreen, and Time-Resolved Fluorescence. The instrument simplifies measurement setup with the automatic dynamic range selection, and its smart safety controls ease workflow and help avoid experimental errors. Varioskan LUX raises the bar for reliability and ease, with technology that works in researchers' best interest.

The Varioskan LUX multimode reader has received HTRF™ certification from Cisbio Bioassays and DLReady™ validation from Promega Corporation.

The Varioskan LUX is a modular, upgradable instrument that provides excellent usability across a variety of applications.
  • Up to five measurement technologies: Absorbance (UV-Vis), Fluorescence intensity (incl. FRET), Luminescence (direct and filtered), AlphaScreen/AlphaLISA and Time-resolved fluorescence (incl. TR-FRET/hTRF)
  • Filter and monochromator optics
  • Spectral scanning for assay optimization
  • Five measurement modes including end point, kinetic, spectra, kinetic spectra and multipoint
  • Integrated gas control module for setting CO2 and O2 concentrations for cell based assays
  • Simultaneous dispensing and measurement for signal monitoring at the start of a reaction
  • Automatic dynamic range selection, based on signal intensity of each well
  • Smart safety controls designed to identify and alert the user of potential problems before they happen
  • Automated instrument calibration and self-diagnostics for reliable performance
  • Certified HTRF compatible reader by CisBio Bioassays
  • Validated DLReady by Promega Corporation
Varioskan LUX is paired with the powerful and intuitive SkanIt Software, providing excellent usability and flexibility.
  • License free—Each user can install the software on his/her computer
  • Intuitive and flexible interface for multiple users and assays
  • Innovative Virtual Pipetting Tool makes it easy to define samples to plate layout
  • Measurement data is continuously saved to the database, so there’s no data lost due to unexpected interruptions such as power outages or accidental aborting
  • Simplified data processing and export
    • Export data in a single mouse click, or have it emailed automatically at the end of the run
    • Several file formats for exporting results: *.xlsx, *.pdf, *.xml, and *.txt
  • Shows real-time spectra and kinetic curves during the measurement
  • Built-in calculations for data analysis (e.g. blank subtraction, average/SD/CV%, standard curve, dose response, quality control, classification, kinetic and spectral analysis, custom formula, etc.)
  • Comprehensive result reports with traceability to runtime actions and settings
  • Two editions available: Research Edition for life science researchers, and Drug Discovery Edition which offers features needed for the FDA 21 CFR Part 11 compliance.
The Varioskan LUX is modular and upgradeable, so you can build the system that best suits your needs. For more information, contact a sales representative.
Specifications
CompatibilityRobot
Detector TypePhotomultiplier Tube (PMT)
Incubator Temperature45°C
InterfacePC Software (Thermo Scientific SkanIt Software)
Light SourceXenon Flash Lamp, LED
Measurement Speed15 s for 96-well Plate, 45 s for 384-well Plate, 135 s for 1536-Well Plate (Minimum Times)
Measurement TechnologyAbsorbance, Fluorescence Intensity, Luminescence, Time-resolved Fluorescence, AlphaScreen
Plate Type6 to 1536-well Plates (Absorbance 6 to 384-well Plates)
Product LineVarioskan
Reading OptionsTop and Bottom
Read-out Range0 to 6 Abs
ShakingOrbital
Software TypeSkanIt Software
Spectral Scanning Speed<2.2 s/Well 400 to 500 nm, 1 Flash, 2 nm Step
Wavelength SelectionDouble Monochromator (Absorbance and Spectral Scanning), Double Excitation and Emission Monochromator (Fluorescence Intensity), Filter (AlphaScreen and Time-Resolved Fluorescence)
Accuracy0.003 Abs or ±2%, at 200 to 399 nm (0 to 2 Abs)
0.003 Abs or ±1%, at 400 to 1000 nm (0 to 3 Abs)
Depth (English)23 in.
Depth (Metric)58 cm
Dispense Volume1 mL syringe: 2 to 5,000 μL
5 mL syringe: 5 to 25,000 μL
Dynamic RangeFluorescence intensity: top reading > 6 decades, bottom reading > 5.5 decades
Time-resolved fluorescence: > 6 decades
Luminescence: > 7 decades
Height (English)20 in.
Height (Metric)51 cm
Linearity96-well plate: ±2% (0 to 4 Abs at 450 nm)
384-well plate: ±2% (0 to 3 Abs at 450 nm)
Measurement TypeEndpoint, Kinetic, Spectra, Multipoint, Kinetic Spectra
No. of Dispensers2
PrecisionSD < 0.001 Abs or CV < 0.5%, at 450 nm (0 to 3 Abs)
SensitivityFluorescence intensity (top reading): < 0.4 fmol fluorescein/well (black 384-well plate)
Fluorescence intensity (bottom reading): < 4 fmol fluorescein/well, (clear bottom black 384 square well plate)
Time-resolved fluorescence: < 1 amol/well (white low volume 384 well plate) Luminescence: < 7 amol ATP/well (white 384-well plate)
AlphaScreen: < 100 amol phosphotyrosine/well (384-well plate)
Software Language VersionsEnglish, German, French, Spanish, Portuguese, Italian, Japansese, Chinese and Russian
Wavelength RangeAbsorbance: 200 to 1000 nm
Fluorescence intensity: Excitation: 200 to 1000 nm, Emission: 270 to 840 nm
Timetoresolved fluorescence: Excitation 334 nm, Emission 400 to 700 nm
Luminescence: 360 to 670 nm
AlphaScreen: Excitation 680 nm, Emission 400 to 660 nm
Weight (English)130 lb.
Weight (Metric)59 kg
Width (English)21 in.
Width (Metric)53 cm
Unit SizeEach