iCAP™ PRO XPS ICP-OES
iCAP™ PRO XPS ICP-OES
Actual product may vary
Thermo Scientific™

iCAP™ PRO XPS ICP-OES

iCAP™ PRO XPS ICP-OES Duo
Have Questions?
Change viewbuttonViewtableView
Catalog NumberDescriptionPlasmViewing
BRE731406iCAP PRO XPS ICP-OES RadialVertical Radial
BRE731407iCAP PRO XPS ICP-OES DuoVertical Radial
Catalog number BRE731406
Price (USD)/ Each
-
Request A Quote
Description:
iCAP PRO XPS ICP-OES Radial
PlasmViewing:
Vertical Radial
Experience high-speed analysis of your trace elemental samples with the Thermo Scientific™ iCAP™ PRO XPS ICP-OES. It meets your specific regulatory requirements with unmatched throughput and versatility.

A benchtop simultaneous ICP spectrometer with a vertical torch, purged echelle polychromator and Charge Injection Device (CID) array detector. The standard configuration includes:

  • a 4-channel, peristaltic pump to allow for the use of advanced accessories.
  • a solid-state, free-running 27.12 MHz RF generator to ensure robust plasma generation for any sample matrix.
  • three independent MFCs to precisely control the nebulizer, plasma, and auxiliary gas and to ensure long-term stability.
  • an option to add an additional gas to the plasma via an integrated MFC with a flow of 0-0.25 L/min, to enable the analysis of high-salt samples (up to 30% TDS) or organics.
  • an interlock drain sensor to shut down the system if a leak in the sample path is detected and to prevent samples from being lost.
  • an echelle polychromator that is thermostatically controlled to ensure long-term stability and reduce the need for recalibration.
  • a cross-dispersing prism combined with an echelle to provide a resolution of 7 pm and minimize interferences.
  • a random-access CID imager that provides full wavelength coverage from 167.021 to 852.145 nm.
  • an enhanced UV mode to allow better sensitivity and detection limits for elements between 167.021 and 240.063 nm via a second UV focused exposure.
  • Thermo Scientific™ Qtegra™ Intelligent Scientific Data Solution™ (ISDS) Software, which provides an easy-to-navigate platform that allows the analyst to add wavelengths, create methods, analyze samples and post-process the data while the spectrometer is acquiring data.
iCAP PRO Series ICP-OES has ACT label certification
Reduce your lab’s environmental impact with the iCAP PRO Series ICP-OES, recipient of the ACT label from My Green Lab. The ACT Environmental Impact Factor Label is the world’s premier eco-label for laboratory products. The program ensures Accountability, Consistency, and Transparency in the reporting of environmental impact data to enable sustainable laboratory procurement. It was designed by both scientists and procurement specialists to provide clear, third-party verified information about the sustainability profile of laboratory products. By providing needed transparency around manufacturing, energy and water use, packaging, and end-of-life impacts, ACT makes it easy to choose environmentally preferable products and reduce the carbon impact of laboratory supply chains.
Specifications
TypeICP-OES Radial
Auxiliary GasMFC tunable via software, adjustable between 0.0 to 2.0 LPM
Detector TypeHigh performance solid-state CID821
Nebulizer GasMFC tunable via software and adjustable between 0.0 to 1.5 LPM
Peristaltic Pump4channelpump,adjustablebetween0and125rpm
Plasma GasMFC tunable via software and adjustable between 0.0 to 20.0 LPM
PlasmViewingVertical Radial
RF Source27 MHz, adjustable between 750 to 1600 W
DescriptioniCAP PRO XPS ICP-OES Radial
Dimensions (D x W x H)690 x 615 x 933 mm
Purge3.4 LPM
Spectral Bandpass7 pm at 200 nm
SpectrometerSimultaneous echelle
Standard Sampling KitConcentric glass nebulizer, Glass cyclonic spray chamber, Semi-demountable EMT torch, 2 mm bore quartz center tube
Warm Up Time5 min. from standby
Wavelength Range167 to 852 nm
Unit SizeEach