1500 Series B2 Bio Safety Cabinets 4ft. and 6 ft.
1500 Series B2 Bio Safety Cabinets 4ft. and 6 ft.
Thermo Scientific

1500 Series B2 Bio Safety Cabinets 4ft. and 6 ft.

NSF listed Class II, Type B2 BSC incorporating SmartFlow intelligent compensation for downflow, energy efficient DC motors and line-of-sight graphical display and user controls for easy access.
Have Questions?
Change viewbuttonViewtableView
Catalog NumberDescriptionVoltage
1565-MAR1500 Series Class II, Type B2 BSC, 6 ft (1.2m) nominal width with UV, 230 VAC, 50/60 Hz with Type M (India) power cord and internal receptacle230 VAC
1510-MAR1500 Series Class II, Type B2 BSC, 4 ft (1.2 m) nominal width, 120V, 50/60Hz115 VAC
1511-MAR1500 Series Class II, Type B2 BSC, 4 ft (1.2 m) nominal width with UV, 120V, 50/60Hz115 VAC
1560-MAR1500 Series Class II, Type B2 BSC, 6 ft (1.8 m) nominal width, 120 V, 50/60 Hz115 VAC
1561-MAR1500 Series Class II, Type B2 BSC, 6 ft (1.8 m) nominal width with UV, 120 V, 50/60 Hz115 VAC
1565M-MAR1500 Series Class II, Type B2 BSC with UV, 6 ft (1.8m) nominal width, 230 VAC, 50/60 Hz with Type M (India) power cord and internal receptacle230 VAC
Catalog number 1565-MAR
Price (USD)/ Each
-
Request A Quote
Description:
1500 Series Class II, Type B2 BSC, 6 ft (1.2m) nominal width with UV, 230 VAC, 50/60 Hz with Type M (India) power cord and internal receptacle
Voltage:
230 VAC
1500 Series B2 BSC, NSF listed Class II, Type B2 BSC available in nominal widths of 4 ft (1.2 m) and 6 ft (1.8m). Regional voltages selectable. Incorporates SmartFlow intelligent compensation for downflow, energy efficient DC motor, stainless steel interior and line-of-sight graphical display and user controls for easy access.
  • NSF listed Class II type B2 BSC
  • SmartFlow intelligent compensation for downflow
  • Energy efficient DC motor
  • Stainless steel interior
  • Line-of-sight graphical display and user controls for easy access
  • Previous models: 1300 Series B2
Specifications
Description1500 Series Class II, Type B2 BSC, 6 ft (1.2m) nominal width with UV, 230 VAC, 50/60 Hz with Type M (India) power cord and internal receptacle
Certifications/ComplianceNSF Class II Type B2 BSC
Width (Metric) Interior1841 mm
Product TypeBiosafety Cabinet
Model1500 Series
Noise Level66 dBA
Power Consumption370 W
Receptacles2 Duplex
Width (English) Exterior78 in.
Volume (Metric) Exhaust1696 m3/hr. (with DIM), 2149 m3/hr. (with Traverse)
Width (Metric) Exterior1981 mm
Width (English) Interior72.5 in.
Voltage230 VAC
Amperage12 A
Energy Consumption (Operating Set Point)0.37 KW
Unit SizeEach