The unique low volume cuvette design guarantees smallest reagent consumption, 2-240 μL, minimizes reagent waste, and as a result reduces reagent costs. Optimized kit sizes and on-board stability further minimize the amount of waste produced and increase cost efficiency.
Save time by eliminating reagent preparation with the Thermo Scientific Gallery system reagents for environmental testing, such as water (clean water, wastewater, soil and sludge digests, effluents, and saline) and industrial (process water) analysis. With over 40 ready-to-use gallery system reagents for environmental analysis, the kits include 1 to 3 reagents in 20 mL barcoded vials, allowing the necessary identification data, such as lot and expiration date, to be read automatically by the discrete analyzer's barcode reader. Automated dilutions make it possible to apply methods for a wide range of analyte concentrations and the test applications are based on recommended standard water and wastewater methods used in most countries. Save time and reduce errors by simplifying your analysis with the Gallery system reagents for environmental analysis.
Benefits
Each vessel is bar coded with all the necessary data including reagent identification, volume, lot, and expiration date. Gallery’s built in barcode reader for sample and reagents Barcode reader improves the traceability and continuously monitors the reagent consumptions and provides real-time reagent information
Thermo Scientific Gallery and Gallery Plus discrete analyzers are easy to use, automated systems that allow laboratories to simplify their testing with the dual benefits of time and cost savings. All necessary analysis steps, startup, calibration, sample dilution are automated, providing true walk-away time for the operator.
Thermo Scientific system reagents are ready to go, saving the technician’s time and reducing errors. Ensuring confidence in the quality of results, the methods used for analysis in the Thermo Scientific discrete analyzers are well known enzymatic and colorimetric chemistries optimized to the result levels established in international reference methods, EPA, ASTM, DIN, ISO, OIV, AOAC, and EBC.
Ready to use reagents are easy to work with eliminating extra preparation steps and saving time and money. Gallery discrete analyzers assure fast, reliable and repeatable results by utilizing specific enzyme reactions, and robust robotics to streamline laboratory analysis.
The unique low volume cuvette design guarantees smallest reagent consumption, 2-240 μL, minimizes reagent waste, and as a result reduces reagent costs. Optimized kit sizes and on-board stability further minimize the amount of waste produced and increase cost efficiency.
Each vessel is bar coded with all the necessary data including reagent identification, volume, lot, and expiration date. Gallery’s built in barcode reader for sample and reagents Barcode reader improves the traceability and continuously monitors the reagent consumptions and provides real-time reagent information
Thermo Scientific Gallery and Gallery Plus discrete analyzers are easy to use, automated systems that allow laboratories to simplify their testing with the dual benefits of time and cost savings. All necessary analysis steps, startup, calibration, sample dilution are automated, providing true walk-away time for the operator.
Thermo Scientific system reagents are ready to go, saving the technician’s time and reducing errors. Ensuring confidence in the quality of results, the methods used for analysis in the Thermo Scientific discrete analyzers are well known enzymatic and colorimetric chemistries optimized to the result levels established in international reference methods, EPA, ASTM, DIN, ISO, OIV, AOAC, and EBC.
Ready to use reagents are easy to work with eliminating extra preparation steps and saving time and money. Gallery discrete analyzers assure fast, reliable and repeatable results by utilizing specific enzyme reactions, and robust robotics to streamline laboratory analysis.
Reagents for Food & Beverage Analysis
Gallery System Reagents for food and beverage analysis are ready-to-use, eliminate extra preparation steps, and save valuable laboratory time. Designed for the Gallery and Thermo Scientific Arena discrete analyzer, the volume-optimized system reagents minimize reagent waste, while continuous monitoring of volume, lot, and expiration dates provides real-time reagent information.
Thermo Scientific Gallery discrete analyzers together with ready to use system reagents makes the overall discrete analysis simple, accurate and reliable.
Each vessel is bar coded with all the necessary data including reagent identification, volume, lot, and expiration date.
Continuous monitoring gives real-time reagent information.
Volume optimized system kits minimize waste.
Required reagent volumes can be up to 15 times smaller when compared to manual methods.
A wide range of calibration standards ensure traceable results.
Ordering information
Catalog number | Description | Analyte | Unit size | Interference filter (nm) main/ side (alternative) | Test range mg/L | Request a quote |
---|---|---|---|---|---|---|
984187 | TON (nitrate + nitrite) by enzymatic reduction system reagents - R1 (275 tests) | Nitrate (TON Enz) | Each | 540/700 (for Gallery) 570 (for Aquakem) | 0 - 25 (for Gallery) 0 - 50 (for Aquakem) | Request a quote |
984350 | TON (nitrate + nitrite) by vanadium reduction system reagents - R1 (360 tests) | Nitrate (TON Vanadium) | Pack of 4 | 540 | 0.4-50 | Request a quote |
984351 | TON (nitrate + nitrite) by vanadium reduction system reagents - R2 (500 tests) | Nitrate (TON Vanadium) | Pack of 4 | 540 | 0.4-50 | Request a quote |
984357 | Chromium (VI) system reagents (480 tests) | Hexavalent Chromium | Pack of 4 | 540/ 880 | 0.1-1.0 | Request a quote |
984358 | Magnesium system reagents (350 tests) | Magnesium (Mg) | Pack of 8 | 510 | 0-400 | Request a quote |
984361 | Calcium (Ca) system reagents (350 tests) | Calcium | Pack of 3 | 660 | 0-1000 | Request a quote |
984362 | Ammonia system reagents - R1 (2000 tests) | Ammonia | Each | 660 | 1.0 - 10.0 (for Gallery) | Request a quote |
984363 | Ammonia system reagents - R2 (1300 tests) | Ammonia | Pack of 4 | 660 | 1.0 - 10.0 (for Gallery) | Request a quote |
984364 | Chloride system reagents - R1 (500 tests) | Chloride | Pack of 4 | 480 | 100 - 500 (for Gallery) 100 - 1000 (for Aquakem) | Request a quote |
984365 | Chloride system reagents - R1 (2500 tests) | Chloride | Pack of 20 | 480 | 100 - 500 (for Gallery) 100 - 1000 (for Aquakem) | Request a quote |
984366 | Phosphate system reagents - R1 (2300 tests) | Phosphate | Pack of 4 | 880 | 1.0-10.0 | Request a quote |
984367 | Phosphate system reagents - R1 (11700 tests) | Phosphate | Pack of 20 | 880 | 1.0-10.0 | Request a quote |
984368 | Phosphate system reagents - R2 (3000 tests) | Phosphate | Pack of 4 | 880 | 1.0-10.0 | Request a quote |
984369 | TON (nitrate + nitrite) by hydrazine reduction system reagents - R1 (1300 tests) | Nitrate (TON Hyd) | Each | 540 | 0 - 25 (for Gallery) 0 - 50 (for Aquakem) | Request a quote |
984370 | TON (nitrate + nitrite) by hydrazine reduction system reagents - R2 (750 tests) | Nitrate (TON Hyd) | Pack of 4 | 540 | 0 - 25 (for Gallery) 0 - 50 (for Aquakem) | Request a quote |
984371 | Nitrite system reagents (1000 tests) | Nitrite | Pack of 4 | 540 | 0 - 25 (for Gallery) 0 - 50 (for Aquakem) | Request a quote |
984372 | Nitrite system reagents (5000 tests) | Nitrite | Pack of 20 | 540 | 0 - 25 (for Gallery) 0 - 50 (for Aquakem) | Request a quote |
984620 | Total Hardness system reagents - R1 (1100 tests) | Total Hardness | Pack of 4 | 620/ 880 | 0-500 | Request a quote |
984621 | Total Hardness system reagents - R2 (975 tests) | Total Hardness | Pack of 4 | 620/ 880 | 0-500 | Request a quote |
984622 | Total Hardness system reagents - R3 (4300 tests) | Total Hardness | Pack of 4 | 620/ 880 | 0-500 | Request a quote |
984623 | Alkalinity system reagents - R1 (975 tests) | Alkalinity | Pack of 4 | 600/ 880 | 0-400 | Request a quote |
984624 | Alkalinity system reagents - R2 (780 tests) | Alkalinity | Pack of 4 | 600/ 880 | 0-400 | Request a quote |
984625 | Silica system reagents - R1 (970 tests) | Silica | Pack of 4 | 700/ 420 | 0-80 | Request a quote |
984626 | Silica system reagents - R2 (1950 tests) | Silica | Pack of 4 | 700/ 420 | 0-80 | Request a quote |
984627 | Silica system reagents - R3 (1950 tests) | Silica | Pack of 4 | 700/ 420 | 0-80 | Request a quote |
984629 | Fluoride system reagents - R1 (2200 tests) | Fluoride | Pack of 4 | 600/ 880 | 0 - 5.0 (for Gallery) 0 - 2.0 (for Aquakem) | Request a quote |
984630 | Fluoride system reagents - R2 (4800 tests) | Fluoride | Pack of 4 | 600/ 880 | 0 - 5.0 (for Gallery) 0 - 2.0 (for Aquakem) | Request a quote |
984631 | Fluoride system reagents - R3 (2200 tests) | Fluoride | Pack of 4 | 600/ 880 | 0 - 5.0 (for Gallery) 0 - 2.0 (for Aquakem) | Request a quote |
984648 | Sulphate system reagents (1100 tests) | Sulphate | Pack of 4 | 420 | 100-500 | Request a quote |
984649 | Sulphate system reagents (5100 tests) | Sulphate | Pack of 6 | 420 | 100-500 | Request a quote |
984652 | TON (nitrate + nitrite) by hydrazine reduction system reagents - R2 (3400 tests) - for Aquakem only | Nitrate (TON Hyd) | Pack of 6 | 540 | 0 - 25 (for Gallery) 0 - 50 (for Aquakem) | Request a quote |
Discrete Analyzer Market Applications
Mastering beer analysis
Dedicated to analysis of beer, malt, and wort, the Gallery Plus Beermaster discrete analyzer automates labor-intensive and time-consuming tests.
Simplified wine analysis
Thermo Scientific Gallery discrete analyzers make wine analysis simple, accurate and reliable. Our ready-to-use system reagents are specifically developed for rapid and cost-effective analysis of juice and wine.
High-throughput environmental analysis
Learn how our discrete analyzers help you comply with the U.S. EPA Clean Water Act (CWA) by automating photometric and electrochemical analysis to provide fast, reproducible results.
Industrial water analysis
To eliminate corrosion and scaling that can damage valuable industrial components and to ensure regulatory compliance, reliable water analysis must be performed continuously.
Enzyme assay analysis
Automation of enzyme assays is becoming increasingly important and the new Gallery Enzyme Master satisfy new method development to routine QA/QC tests.
Environmental & industrial applications compendium
Discover how Gallery Discrete Analyzers offer simultaneous, multi-parameter nutrient analysis for drinking water, wastewater, sewage water, soil and fertilizer and plant extract samples.
Resources
Gallery System Reagents for Water/Environmental Samples
Specification sheet summarizes regulatory methods, working range, number of tests and sample matrix for the ready to use reagent kits for water and environmental samples.
Gallery System Reagents for Food and Other Sample Materials
Specification sheet summarizes regulatory methods, working range, number of tests and sample matrix for the ready to use reagent kits for water and environmental samples.
Fast and Accurate Gallery Discrete Industrial Analyzers — Automated Nutrient Analysis and Water Quality Monitoring
Thermo Scientific Gallery analyzers are sophisticated discrete photometric systems for the precise and easily adaptable analysis of water and environmental samples.
Brochure for automated wet chemical analysis
The brochure presents how the Thermo Scientific Gallery discrete analyzers can help growing laboratories perform food and beverage analysis, and environmental water analysis by automating multiparameter wet chemical analysis.
Environmental and industrial analysis webinars
Browse our searchable database of on-demand webinars about discrete industrial analyzers for environmental and industrial analysis to find methods and applications to accelerate the work in your lab.
Detection of sulfate in drinking water
Learn how a novel discrete analyzer-based automated method for compliance measurements of sulfate follows the US EPA Safe Drinking Water Act (SDWA).
Automated chloride analysis method for drinking water samples
A novel discrete analyzer-based automated method for drinking water chloride testing for compliance measurements that follows the United States Environmental Protection Agency (U.S. EPA) Safe Drinking Water Act (SDWA).
Search automated wet chemistry analysis resources
No records were found matching your criteria